SOFTWARE AND METHODS FOR PRECISE X-RAY-ANALYSIS

被引:10
|
作者
CHERNYSHEV, VV
FETISOV, GV
LAKTIONOV, AV
MARKOV, VT
NESTERENKO, AP
ZHUKOV, SG
机构
[1] Moscow State Univ, Moscow
关键词
D O I
10.1107/S0021889891014243
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The software package PPXA (programs for precise X-ray analysis) is described, which provides crystallographers with increased precision and reliability of the results of X-ray analysis. The package includes programs for: testing the quality of an automatic four-circle X-ray diffractometer before X-ray experiments; optimization of X-ray diffraction experiments; preliminary processing of experimental data; precise structure analysis up to electron density distribution. The programs for diffractometer testing allow the experimenter to check the stability and precision of the instrument, the homogeneity of the X-ray beam and the detector sensitivity. The programs for preliminary data processing include: corrections for absorption, taking into account the intensity distribution in the X-ray beam cross section; correction or elimination of the simultaneous reflection effect; background subtraction, correcting the effects of the scan-interval cut-off; correction for thermal diffuse scattering (TDS) for crystals in cases of both known and unknown elasticity constants. The programs for precise crystal structure refinement include options for the determination of primary- and secondary-extinction parameters, atomic coordinates, thermal-vibration parameters in harmonic and anharmonic approximations, occupation of atomic positions, atom-core and valence-shell occupation parameters. The programs were written for a MicroVAX-II computer with a VAX/VMS operating system and designed to work with CAD-4 diffractometers and the SDP-Plus software package. A suitable dialogue with a menu system and detailed user's instructions are available.
引用
收藏
页码:451 / 454
页数:4
相关论文
共 50 条
  • [1] Software and methods for precise X-ray analysis
    Chernyshev, V.V.
    Fetisov, G.V.
    Laktionov, A.V.
    Markov, V.T.
    Nesterenko, A.P.
    Zhukov, S.G.
    Journal of Applied Crystallography, 1992, 25 (pt 3): : 451 - 454
  • [2] X-RAY-ANALYSIS
    不详
    CHEMICAL & ENGINEERING NEWS, 1987, 65 (12) : 75 - 76
  • [3] COMPARISON BETWEEN 2 X-RAY-ANALYSIS SOFTWARE PACKAGES
    BOMAN, J
    ISAKSON, J
    X-RAY SPECTROMETRY, 1991, 20 (06) : 305 - 314
  • [4] X-RAY-ANALYSIS OF IONOMERS
    REGISTER, RA
    DING, YS
    FOUCART, M
    JEROME, R
    HUBBARD, SR
    HODGSON, KO
    COOPER, SL
    ACS SYMPOSIUM SERIES, 1989, 395 : 420 - 438
  • [5] ADVANCES IN X-RAY-ANALYSIS
    MULLER, R
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-LEIPZIG, 1965, 228 (3-4): : 285 - &
  • [6] SYNCHROTRON RADIATION X-RAY-ANALYSIS
    GOHSHI, Y
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1987, 27 (02) : B40 - B40
  • [7] IS ACCURATE X-RAY-ANALYSIS WORTHWHILE
    DUNITZ, JD
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1988, 61 (01) : 1 - 11
  • [8] X-RAY-ANALYSIS OF SPHERICAL VIRUSES
    MORGUNOVA, EY
    MIKHAILOV, AM
    VAINSHTEIN, BK
    MOLECULAR BIOLOGY, 1993, 27 (02) : 225 - 232
  • [9] X-RAY-ANALYSIS FOR PRODUCTION CONTROL
    PRICE, BJ
    AMERICAN LABORATORY, 1981, 13 (08) : 66 - 71
  • [10] X-RAY-ANALYSIS OF ANAEROBIC GRANULES
    FANG, HHP
    LIU, Y
    BIOTECHNOLOGY TECHNIQUES, 1995, 9 (07) : 513 - 518