ANALYSIS OF STYRENE OLIGOMERS BY PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:24
|
作者
JONES, GG [1 ]
PAULS, RE [1 ]
WILLOUGHBY, RC [1 ]
机构
[1] EXTREL CORP,PITTSBURGH,PA 15238
关键词
D O I
10.1021/ac00005a015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have investigated the transport properties of a particle beam liquid chromatograph/mass spectrometer interface using oligomers of polystyrene as test molecules. The polystyrene system was chosen because it is available in a well-defined series of oligomers spanning the mass range of our spectrometer and because polystyrene is known to undergo thermal degradation in a conventional solids insertion probe inlet. The results indicate that intact styrene oligomers with molecular weights up to approximately 2000 were quantitatively transferred through the interface and into the mass spectrometer ion source. Using electron impact ionization, we observed molecular ions out to the n = 18 oligomer at mass 1930, well beyond the highest reported molecular ion detected by using solids insertion probe sample introduction systems.
引用
收藏
页码:460 / 463
页数:4
相关论文
共 50 条
  • [21] AN ONLINE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY MASS-SPECTROMETRY EXPERIMENT
    VOYKSNER, RD
    HASS, JR
    BURSEY, MM
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1982, 15 (01): : 1 - 12
  • [22] POLY(AMIC ACID) AND POLYIMIDE CHARACTERIZATION USING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND PARTICLE-BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    MACMAHON, T
    CHACE, M
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (04) : 299 - 304
  • [23] MASS-SPECTROMETRY OF STYRENE OLIGOMERS
    BECKEWITZ, F
    HEUSINGER, H
    ANGEWANDTE MAKROMOLEKULARE CHEMIE, 1975, 46 (AUG5): : 143 - 150
  • [24] LIQUID-CHROMATOGRAPHY COUPLED WITH MASS-SPECTROMETRY IN THE ANALYSIS OF ALKALOIDS
    VERPOORTE, R
    NIESSEN, WMA
    PHYTOCHEMICAL ANALYSIS, 1994, 5 (05) : 217 - 232
  • [25] ANALYSIS OF RNA HYDROLYZATES BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    POMERANTZ, SC
    MCCLOSKEY, JA
    METHODS IN ENZYMOLOGY, 1990, 193 : 796 - 824
  • [26] LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN ENVIRONMENTAL-ANALYSIS
    CARERI, M
    MANINI, P
    MASPERO, M
    ANNALI DI CHIMICA, 1994, 84 (11-12) : 475 - 508
  • [27] CAPILLARY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    TOMER, KB
    MOSELEY, MA
    DETERDING, LJ
    PARKER, CE
    MASS SPECTROMETRY REVIEWS, 1994, 13 (5-6) : 431 - 457
  • [28] ANALYSIS OF EXPLOSIVES BY LIQUID-CHROMATOGRAPHY THERMOSPRAY MASS-SPECTROMETRY
    BERBERICH, DW
    YOST, RA
    FETTEROLF, DD
    JOURNAL OF FORENSIC SCIENCES, 1988, 33 (04) : 946 - 959
  • [29] THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IN PHYTOCHEMICAL ANALYSIS
    WOLFENDER, JL
    MAILLARD, M
    HOSTETTMANN, K
    PHYTOCHEMICAL ANALYSIS, 1994, 5 (04) : 153 - 182
  • [30] ANALYSIS OF INTACT OLIGOSACCHARIDES BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    NIESSEN, WMA
    VANDERHOEVEN, RAM
    VANDERGREEF, J
    ORGANIC MASS SPECTROMETRY, 1992, 27 (03): : 341 - 342