PLANAR DOUBLE DELAY-LINE READOUT TECHNIQUE FOR MICROCHANNEL PLATE DETECTORS

被引:9
|
作者
LAMPTON, M
SIEGMUND, OHW
RAFFANTI, R
机构
[1] University of California, Berkeley, Space Sciences Laboratory, Berkeley
基金
美国国家航空航天局;
关键词
D O I
10.1109/23.55868
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A two-dimensional position-sensitive electrical readout system for microchannel plate detectors in spectroscopic applications has been devised. Two adjacent parallel coplanar delay lines are employed. The difference in time of arrival of the electron event signal between the ends of the delay lines gives one coordinate of the centroid of each event pulse. The ratio of the event amplitudes on the two delay lines gives the orthogonal coordinate by means of charge partitioning. The performance characteristics of operational double delay lines for systems of this type are presented. © 1990 IEEE
引用
收藏
页码:1548 / 1549
页数:2
相关论文
共 50 条
  • [41] FPGA implementation of a delay-line readout system for a particle detector
    Seferiadis, G
    Pouchet, M
    Gough, MP
    MEASUREMENT, 2006, 39 (01) : 90 - 99
  • [42] Study of Delay-line Readout for Boron Coated Straw detector
    Yu, Hao
    Gong, Hui
    Wang, Yongqiang
    Wang, Xuewu
    Li, Jianmin
    Li, Yuanjing
    Kang, Kejun
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [43] DUAL TIME TO DIGITAL CONVERTER FOR DELAY-LINE READOUT OF POSITION-SENSITIVE GAS-FILLED DETECTORS
    BERRY, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05): : 1222 - 1228
  • [44] A data acquisition system for two-dimensional position sensitive micropattern gas detectors with delay-line readout
    Hanu, A. R.
    Prestwich, W. V.
    Byun, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 780 : 33 - 39
  • [45] A FAST READOUT SYSTEM FOR 2D GAS-FILLED DETECTORS BASED ON THE DELAY-LINE METHOD
    BERRY, A
    GABRIEL, A
    KOCSIS, M
    RIEKEL, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 334 - 337
  • [46] DATA ACQUISITION-SYSTEMS FOR LINEAR AND AREA X-RAY-DETECTORS USING DELAY-LINE READOUT
    BOULIN, CJ
    KEMPF, R
    GABRIEL, A
    KOCH, MHJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (01): : 312 - 320
  • [47] PROGRAMMABLE PLANAR FOLDED PATH SAW DELAY-LINE
    CHO, FY
    HUNSINGER, BJ
    LEE, LL
    ENRIGHT, J
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1975, SU22 (03): : 214 - 214
  • [48] DOUBLE SERIAL AMPLIFIED RECIRCULATING DELAY-LINE
    VIZOSO, B
    CIVERA, R
    LOPEZ-AMO, M
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1993, 6 (13) : 766 - 768
  • [49] HIGH-RESOLUTION READOUT OF MULTIWIRE PROPORTIONAL COUNTERS USING CATHODE COUPLED DELAY-LINE TECHNIQUE
    LACY, JL
    LINDSEY, RS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 562 - 563
  • [50] Multiple hit read-out of a microchannel plate detector with a three-layer delay-line anode
    Jagutzki, O
    Cerezo, A
    Czasch, A
    Dörner, R
    Hattass, M
    Huang, M
    Mergel, V
    Spillmann, U
    Ullmann-Pfleger, K
    Weber, T
    Schmidt-Böcking, H
    Smith, G
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 850 - 854