摘要
A two-dimensional position-sensitive electrical readout system for microchannel plate detectors in spectroscopic applications has been devised. Two adjacent parallel coplanar delay lines are employed. The difference in time of arrival of the electron event signal between the ends of the delay lines gives one coordinate of the centroid of each event pulse. The ratio of the event amplitudes on the two delay lines gives the orthogonal coordinate by means of charge partitioning. The performance characteristics of operational double delay lines for systems of this type are presented. © 1990 IEEE
引用
收藏
页码:1548 / 1549
页数:2
相关论文
共 50 条
  • [1] DELAY-LINE READOUT OF MICROCHANNEL PLATES
    SOBOTTKA, SE
    WILLIAMS, MB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 348 - 351
  • [2] DELAY-LINE READOUT FOR MULTICELL DETECTORS
    DITTA, J
    KURODA, K
    NEMOZ, C
    SILLOU, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 250 (03): : 539 - 542
  • [3] Research on the delay-line readout for GEM detectors
    Zhou Yi
    Li Cheng
    CHINESE PHYSICS C, 2008, 32 : 232 - 234
  • [4] DIRECT TIME DIGITIZING FOR DETECTORS WITH DELAY-LINE READOUT
    BOULIN, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01): : 237 - 239
  • [5] A HIGH-RESOLUTION DELAY-LINE READOUT FOR MICROCHANNEL PLATES
    SIEGMUND, OHW
    LAMPTON, ML
    RAFFANTI, R
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 476 - 485
  • [6] Multiple hit readout of a microchannel plate detector with a three-layer delay-line anode
    Jagutzki, O
    Cerezo, A
    Czasch, A
    Dörner, R
    Hattass, M
    Huang, M
    Mergel, V
    Spillmann, U
    Ullmann-Pfleger, K
    Weber, T
    Schmidt-Böcking, H
    Smith, GDW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2477 - 2483
  • [7] DELAY-LINE ANODES FOR MICROCHANNEL-PLATE SPECTROMETERS
    LAMPTON, M
    SIEGMUND, O
    RAFFANTI, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (12): : 2298 - 2305
  • [8] IMAGING PROPERTIES OF A DELAY-LINE READOUT USING LARGE MICROCHANNEL PLATES
    SHEPHERD, JA
    SOBOTTKA, SE
    WILLIAMS, MB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 154 - 157
  • [9] EVALUATION OF AN IMAGING PHOTOTUBE USING MICROCHANNEL PLATES WITH DELAY-LINE READOUT
    WILLIAMS, MB
    SOBOTTKA, SE
    SHEPHERD, JA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 148 - 153
  • [10] Optimization of the readout electronics for microchannel plate delay line anodes
    Vallerga, J
    McPhate, J
    INSTRUMENTATION FOR UV/EUV ASTRONOMY AND SOLAR MISSIONS, 2000, 4139 : 34 - 42