AN AUDIT OF INDUCTION OF ANESTHESIA IN NEONATES AND SMALL INFANTS USING PULSE OXIMETRY

被引:20
|
作者
KONG, AS
BRENNAN, L
BINGHAM, R
MORGANHUGHES, J
机构
[1] NORFOLK & NORWICH HOSP,NORWICH NR1 3SR,NORFOLK,ENGLAND
[2] HOSP SICK CHILDREN,LONDON WC1N 3JH,ENGLAND
关键词
ANESTHESIA; PEDIATRIC; AUDIT; MONITORING; PULSE OXIMETRY;
D O I
10.1111/j.1365-2044.1992.tb03159.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The frequency and seventy of hypoxaemia during induction of anaesthesia in neonates and small infants at the Norfolk and Norwich Hospital, a district general hospital, was compared, using pulse oximetry, with that of the nearest specialist hospital, the Queen Elizabeth Hospital for Sick Children in London. There were differences in staffing and the choice of anaesthetic techniques between the hospitals. One third of the patients in both hospitals experienced desaturation of more than 5% (moderate or severe hypoxaemia) at one or more recordings during induction. The highest incidence of hypoxaemia was associated with awake intubation. There was no statistical difference in the incidence or severity of hypoxaemia between the hospitals. In the district general hospital, moderate or severe hypoxaemia of greater than 30 s duration was more likely if an anaesthetist with a regular paediatric operating list was not present at induction (p < 0.01). Copyright © 1992, Wiley Blackwell. All rights reserved
引用
收藏
页码:896 / 899
页数:4
相关论文
共 50 条
  • [31] Inpatient comparison of wireless and wired pulse oximetry in neonates
    Harrell, Mathew
    Dobson, Nicole
    Olsen, Cara
    Ahmed, Anwar
    Hunt, Carl
    JOURNAL OF NEONATAL-PERINATAL MEDICINE, 2022, 15 (02) : 283 - 289
  • [32] Safe anesthesia for neonates, infants and children
    Raviraj, Divya
    Engelhardt, Thomas
    Giedsing Hansen, Tom
    MINERVA PEDIATRICA, 2018, 70 (05) : 458 - 466
  • [33] Normal pulse oximetry values in infants and children
    Mau, MK
    Yamasato, K
    Yamamoto, LG
    PEDIATRIC RESEARCH, 2003, 53 (04) : 575A - 575A
  • [34] ACCURACY AND PRECISION OF PULSE OXIMETRY IN HYPOXEMIC INFANTS
    Foglia, E.
    Whyte, R.
    Chaudhary, A.
    Mott, A.
    Chen, J.
    Propert, K.
    Schmidt, B.
    EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (11) : 1584 - 1585
  • [35] PULSE OXIMETRY ADVANTAGES IN INFANTS WITH BRONCHOPULMONARY DYSPLASIA
    SOLIMANO, AJ
    SMYTH, JA
    MANN, TK
    ALBERSHEIM, SG
    LOCKITCH, G
    PEDIATRICS, 1986, 78 (05) : 844 - 849
  • [36] PULSE OXIMETRY DURING KETAMINE ANESTHESIA IN WAR CONDITIONS
    PESONEN, P
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (05): : 592 - 594
  • [37] ORAL PULSE OXIMETRY IN SMALL CHILDREN
    LEMA, GE
    ANESTHESIA AND ANALGESIA, 1991, 72 (03): : 414 - 414
  • [38] CRITICAL INCIDENTS DETECTED BY PULSE OXIMETRY DURING ANESTHESIA
    MCKAY, WPS
    NOBLE, WH
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1988, 35 (03): : 265 - 269
  • [39] Evaluation of pulse oximetry as a monitoring method in avian anesthesia
    Schmitt, PM
    Gobel, T
    Trautvetter, E
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 1998, 12 (02) : 91 - 99
  • [40] Pulse oximetry in small animal medicine
    Engel, Larissa
    Doerfelt, Rene
    KLEINTIERPRAXIS, 2018, 63 (03): : 140 - 152