Wavelength calibration method for a CCD detector and multichannel fiber-optic probes

被引:44
作者
Cho, JH
Gemperline, PJ
Walker, D
机构
[1] E CAROLINA UNIV, DEPT CHEM, GREENVILLE, NC 27858 USA
[2] GLAXO WELLCOME CO, ANALYT DEV LABS, GREENVILLE, NC 27835 USA
关键词
spectrometer; wavelength calibration; multichannel fiber optics; charge-coupled device; tablet dissolution test;
D O I
10.1366/0003702953966055
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A wavelength calibration method for a charge-coupled device (CCD) array detector and seven-channel fiber-optic spectrograph is described. The method was developed for the extraction of wavelength-calibrated spectra for in situ dissolution testing of tablets. The method includes automatic recognition of the positions of the seven fiber channels and recognition of mercury line positions in pixel numbers. A wavelength calibration model with two trigonometric terms was used for least-squares fitting of horizontal pixel numbers to the known wavelengths of five lines from a low-pressure mercury discharge lamp. Four other models were used for comparison. The standard error of estimate (SEE) was minimum for the model with two trigonometric terms. Each fiber channel was calibrated separately. After least-squares fitting, linear interpolation was used to obtain the wavelength-calibrated spectra in the range of 190-450 nm at 1-nm intervals. With this method, spectra from seven fiber-optic probes can be acquired simultaneously and rapidly for in situ dissolution testing. The wavelength calibration procedure is good enough to permit solution spectra acquired on one channel to be used for multivariate calibration of the other channels under appropriate circumstances.
引用
收藏
页码:1841 / 1845
页数:5
相关论文
共 10 条
[1]   ULTRAVIOLET VISIBLE PHOTODIODE ARRAY SPECTROPHOTOMETER WAVELENGTH CALIBRATION METHOD - A PRACTICAL COMPUTER ALGORITHM [J].
BERLOT, PE ;
LOCASCIO, GA .
ANALYST, 1991, 116 (03) :313-316
[2]   WAVELENGTH CALIBRATION METHODS FOR LOW-RESOLUTION PHOTODIODE-ARRAY SPECTROMETERS [J].
BROWNRIGG, JT .
APPLIED SPECTROSCOPY, 1993, 47 (07) :1007-1014
[3]  
CHO JH, 1995, IN PRESS ANAL CHEM
[4]   WAVELENGTH CALIBRATION OF OPTICAL MULTICHANNEL DETECTORS IN COMBINATION WITH SINGLE-GRATING AND DOUBLE-GRATING MONOCHROMATORS [J].
LINDRUM, M ;
NICKEL, B .
APPLIED SPECTROSCOPY, 1989, 43 (08) :1427-1431
[5]   BINOMIAL SMOOTHING FILTER - A WAY TO AVOID SOME PITFALLS OF LEAST-SQUARES POLYNOMIAL SMOOTHING [J].
MARCHAND, P ;
MARMET, L .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (08) :1034-1041
[6]   GEOMETRIC THEORY OF GRATING [J].
NODA, H ;
NAMIOKA, T ;
SEYA, M .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1974, 64 (08) :1031-1036
[7]   CHARACTERIZATION OF A COMPUTERIZED PHOTODIODE ARRAY SPECTROMETER FOR GAS-CHROMATOGRAPHY ATOMIC EMISSION-SPECTROMETRY [J].
SULLIVAN, JJ ;
QUIMBY, BD .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1034-1043
[8]   WAVELENGTH CALIBRATION OF A MULTICHANNEL SPECTROMETER [J].
TSENG, CH ;
FORD, JF ;
MANN, CK ;
VICKERS, TJ .
APPLIED SPECTROSCOPY, 1993, 47 (11) :1808-1813
[9]  
1987, ANN BOOK ASTM STANDA, pE275
[10]  
1993, CONCAVE DIFFRACTION