MECHANICAL AND DOSIMETRIC QUALITY-CONTROL FOR COMPUTER-CONTROLLED RADIOTHERAPY TREATMENT EQUIPMENT

被引:6
作者
THOMPSON, AV
LAM, KL
BALTER, JM
MCSHAN, DL
MARTEL, MK
WEAVER, TA
FRAASS, BA
TENHAKEN, RK
机构
[1] Department of Radiation Oncology, University of Michigan Medical Cente, Ann Arbor
关键词
QUALITY CONTROL; COMPUTER CONTROL; RACETRACK MICROTRON; CONFORMAL RADIOTHERAPY; CCRS SEQUENCE PROCESSOR;
D O I
10.1118/1.597542
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modern computer controlled radiotherapy treatment equipment offers the possibility of delivering complex, multiple field treatments with minimal operator intervention, thus making multiple field conformal therapy practical. Conventional quality control programs are inadequate for this new technology, so new quality control procedures are needed. A reasonably fast, sensitive, and complete daily quality control program has been developed in our clinic that includes nearly automated mechanical as well as dosimetric tests. Automated delivery of these quality control fields is performed by the control system of the MM50 racetrack microtron, directed by the CCRS sequence processor [D. L. McShan and B. A. Fraass, Proceedings of the Xlth International Conference on the use of computers in Radiation Therapy, 20–24 March 1994, Manchester, U.K. (North Western Medical Physics Department, Manchester, U.K., 1994), pp. 210–211], which controls the treatment process. The mechanical tests involve multiple irradiations of a single film to check the accuracy and reproducibility of the computer controlled setup of gantry and collimator angles, table orientation, collimator jaws, and multileaf collimator shape. The dosimetric tests, which involve multiple irradiations of an array of ionization chambers in a commercial dose detector (Keithly model 90100 Tracker™ System) rigidly attached to the head of the treatment gantry, check the output and symmetry of the treatment unit as a function of gantry and collimator angle and other parameters. For each of the dosimetric tests, readings from the five ionization chambers are automatically read out, stored, and analyzed by the computer, along with the geometric parameters of the treatment unit for that beam. The present work describes in detail these quality control tests that have been implemented in our clinic to help confirm the mechanical and dosimetric consistency of an MM50 racetrack microtron system [Masterson et al, Int. J. Radiat. Oncol. Biol. Phys. 28, 1219–1227 (1994)]. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:563 / 566
页数:4
相关论文
共 6 条
  • [1] LICHTER AS, 1994, PRINCIPLES PRACTICE, V8
  • [2] LING CC, 1993, RADIOTHER ONCOL, V29, P129
  • [3] PRECLINICAL EVALUATION OF THE RELIABILITY OF A 50 MEV RACETRACK MICROTRON
    MASTERSON, ME
    MAGERAS, GS
    LOSASSO, T
    JORESKOG, E
    LARSSON, LG
    TSIRAKIS, B
    FEBO, R
    MOHAN, R
    LING, CC
    LEIBEL, SA
    FUKS, Z
    KUTCHER, GJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1219 - 1227
  • [4] MCSHAN DL, 1994, 11TH P INT C US COMP, P210
  • [5] WANG Q, 1994, 11TH P INT C US COMP, P212
  • [6] KEITHLEY MODEL 90100