THERMAL PERFORMANCE OF FLAT PLATE PULSATING HEAT PIPES WITH MINI- AND MICROCHANNELS

被引:8
作者
Jang, Dong Soo [1 ]
Lee, Eun-Ji [1 ]
Lee, Sang Hun [1 ]
Kim, Yongchan [2 ]
机构
[1] Korea Univ, Grad Sch Mech Engn, Seoul 136713, South Korea
[2] Korea Univ, Dept Mech Engn, Seoul 136713, South Korea
关键词
Pulsating heat pipes; minichannels; microchannels; thermal performance; distilled water;
D O I
10.1142/S2010132514500254
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents the thermal performance of pulsating heat pipes (PHPs) using distilled water with mini- and microchannels. The PHPs were fabricated with the channels of square cross section which had hydraulic diameters ranged from 1.6 to 3.2 mm in minichannels and from 0.714 to 0.941 mm in microchannels. The performance of the PHPs was measured and analyzed by varying hydraulic diameter, number of turns,filling ratio, and input power. The filling ratio of the working fluid varied from 0% to 100%. The input power was controlled in the range between 3.6 and 150 W. The hydraulic diameter, number of turns,filling ratio, and input power showed strong influence on the performance of the PHP. In the PHP models with mini-and microchannels, optimum working conditions, such asfilling ratio and heat input, were quite different according to channel size.
引用
收藏
页数:7
相关论文
共 16 条
  • [1] Closed loop pulsating heat pipes - Part A: parametric experimental investigations
    Charoensawan, P
    Khandekar, S
    Groll, M
    Terdtoon, P
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (16) : 2009 - 2020
  • [2] A novel design of pulsating heat pipe with fewer turns applicable to all orientations
    Chien, Kuo-Hsiang
    Lin, Yur-Tsai
    Chen, Yi-Rong
    Yang, Kai-Shing
    Wang, Chi-Chuan
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (21-22) : 5722 - 5728
  • [3] Kang S. W., 2011, INT J AIR COND REFRI, V19, P17
  • [4] Understanding operational regimes of closed loop pulsating heat pipes: an experimental study
    Khandekar, S
    Dollinger, N
    Groll, M
    [J]. APPLIED THERMAL ENGINEERING, 2003, 23 (06) : 707 - 719
  • [5] Effect of silver nano-fluid on pulsating heat pipe thermal performance
    Lin, Yu-Hsing
    Kang, Shung-Wen
    Chen, Hui-Lun
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1312 - 1317
  • [6] Fabrication of polydimethylsiloxane (PDMS) pulsating heat pipe
    Lin, Yu-Hsing
    Kang, Shung-Wen
    Wu, Tsung-Yu
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) : 573 - 580
  • [7] Experimental study on effective range of miniature oscillating heat pipes
    Lin, Zirong
    Wang, Shuangfeng
    Chen, Jinjian
    Huo, Jiepeng
    Hu, Yanxin
    Zhang, Winston
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (05) : 880 - 886
  • [8] Local heat transfer measurement and thermo-fluid characterization of a pulsating heat pipe
    Mameli, Mauro
    Marengo, Marco
    Khandekar, Sameer
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 75 : 140 - 152
  • [9] Experimental study on the thermal performance of vertical closed-loop oscillating heat pipes and correlation modeling
    Qu, Jian
    Wang, Qian
    [J]. APPLIED ENERGY, 2013, 112 : 1154 - 1160
  • [10] Start-up, heat transfer and flow characteristics of silicon-based micro pulsating heat pipes
    Qu, Jian
    Wu, Huiying
    Cheng, Ping
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (21-22) : 6109 - 6120