ON THE RESPONSE TO FAST NEUTRONS OF A BF3 COUNTER IN A PARAFFIN SPHERICAL-HOLLOW MODERATOR

被引:4
|
作者
LADU, M
PELLICCIONI, M
ROTONDI, E
机构
来源
NUCLEAR INSTRUMENTS & METHODS | 1963年 / 23卷 / 01期
关键词
D O I
10.1016/0029-554X(63)90036-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:173 / 174
页数:2
相关论文
共 50 条
  • [31] Response matrix of a neutron spectroscopy system comprised of successive BF3 and H2O arrays
    Elgohary, M. E.
    Aljohani, M. S.
    Khalil, M. Y.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2009, 48 (02): : 21201p1 - 21201p8
  • [32] GEANT4 Monte Carlo simulation response of parallel plate avalanche counter for fast neutrons detection
    Jamil, M.
    Jo, Hyun Yong
    Rhee, J. T.
    Jeon, Y. J.
    RADIATION MEASUREMENTS, 2012, 47 (04) : 277 - 280
  • [33] Measurements of fast neutrons above ground and in 47 m depth with a 3He proportional counter
    S. Niese
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 272 : 173 - 176
  • [34] Measurements of fast neutrons above ground and in 47 m depth with a 3He proportional counter
    Niese, S.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 272 (01) : 173 - 176
  • [35] EXPERIMENTAL VERIFICATION OF FLATNESS OF RESPONSE OF A MULTI-BF3-COUNTER NEUTRON DETECTION SYSTEM
    CRAWFORD, DM
    THOMAS, BW
    BOTTCHER, K
    KOCH, R
    THIES, HH
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (02): : 311 - 315
  • [36] Response of LaBr3:Ce scintillation detector itself to fast neutrons
    Liu, C.
    Ma, H.
    Pan, X.
    Zeng, Z.
    Li, J.
    Zhang, H.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [37] Analysis of the LaCl3(Ce) scintillator response function to fast neutrons
    Pankratenko, A. V.
    Kormilitsyn, T. M.
    Kashuck, Yu. A.
    Obudovsky, S. Yu.
    Fridrikhsen, D. S.
    Shevelev, A. E.
    Khilkevitch, E. M.
    Iliasova, M. V.
    Bakharev, N. N.
    Skrekel, O. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1052
  • [38] Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters
    Kudo, K
    Takeda, N
    Uritani, A
    Koshikawa, S
    Shibata, Y
    Kobayashi, K
    Yoshimoto, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 305 - 309
  • [39] LOW-LEVEL GAMMA AND NEUTRON MONITORING BASED ON USE OF PROPORTIONAL COUNTER FILLED WITH 3HE IN POLYTHENE MODERATOR: STUDY OF THE RESPONSES TO GAMMA AND NEUTRONS
    Pszona, S.
    Bantsar, A.
    Tulik, P.
    Wincel, K.
    Zareba, B.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 237 - 240
  • [40] Relative Enhancement of a 3He Ion Chamber Response to Fast Neutrons by TOF Rejection of Slow Neutrons With a Pulsed Neutron Source
    Matysiak, Witold
    Chin, Kenrick
    McMaster, Scott
    Prestwich, William V.
    Byun, Soo Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 266 - 271