REPOSITIONING A TILTED CILIARY-SULCUS-FIXATED INTRAOCULAR-LENS

被引:0
作者
BERGER, RR [1 ]
KENYERES, A [1 ]
VANCOLLER, BM [1 ]
PRETORIUS, CF [1 ]
机构
[1] BOKSBURG BENONI HOSP,BOKSBURG,SOUTH AFRICA
关键词
CILIARY SULCUS; INTRAOCULAR LENS; POLYPROPYLENE; TRANSSCLERAL FIXATION;
D O I
10.1016/S0886-3350(13)80203-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To correct the problem of intraocular lens tilt after ciliary sulcus fixation, we developed a simple technique that uses one half of a 10-0 polypropylene suture.