IMPLEMENTATION OF THE ETAR METHOD FOR 3D INHOMOGENEITY CORRECTION USING FFT

被引:15
|
作者
YU, CX
WONG, JW
机构
[1] William Beaumont Hospital, Royal Oak, Michigan
关键词
D O I
10.1118/1.597010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The equivalent tissue-air-ratio (ETAR) method employs three-dimensional (3D) CT pixel information to approximate scatter dose contribution for inhomogeneity correction. In general, the calculation provides better agreement with measurements than the one-dimensional (1D) methods typically used in commercial treatment planning systems. In its original implementation, the 3D formulation of the ETAR method is modified empirically as a 2D calculation in order to reduce computation time. The modification compromises the use of the method in several treatment geometries. An examination of the ETAR formulation shows that the calculation can be expressed as a convolution and thus can be performed in 3D using fast Fourier transform (FFT) techniques. The algorithm has been implemented as a 3D FFT convolution. Making use of the symmetric properties of the FFT, the new approach shows significant savings in computation time without excessive memory requirement. Despite its fundamental limitations when applied to regions of electronic disequilibrium, the ETAR method offers a practical solution to improving current dose calculation in 3D treatment planning, particularly when the more advanced scatter ray-tracing dose calculation algorithms remain impractical for clinical use. Recent work to extend the method to approximate electron transport is also encouraging.
引用
收藏
页码:627 / 632
页数:6
相关论文
共 50 条
  • [1] 3D space charge code with the FFT method
    赵亚亮
    傅世年
    李智慧
    徐成海
    杨晓宇
    Chinese Physics C, 2013, (03) : 97 - 100
  • [2] 3D space charge code with the FFT method
    Zhao Ya-Liang
    Fu Shi-Nian
    Li Zhi-Hui
    Xu Cheng-Hai
    Yang Xiao-Yu
    CHINESE PHYSICS C, 2013, 37 (03)
  • [3] Velocity Filtering Using Quantum 3D FFT
    Koukiou, Georgia
    Anastassopoulos, Vassilis
    PHOTONICS, 2023, 10 (05)
  • [4] 3D FFT for FPGAs
    Humphries, Ben
    Herbordt, Martin C.
    2013 IEEE CONFERENCE ON HIGH PERFORMANCE EXTREME COMPUTING (HPEC), 2013,
  • [5] Progressive damage analysis of 3D braided composites using FFT-based method
    Wang, Bing
    Fang, Guodong
    Liu, Shuo
    Fu, Maoqing
    Liang, Jun
    COMPOSITE STRUCTURES, 2018, 192 : 255 - 263
  • [6] FIRST RESULTS ON THE COMPUTATION OF TERRAIN CORRECTIONS BY THE 3D FFT METHOD
    PENG, M
    LI, YC
    SIDERIS, MG
    MANUSCRIPTA GEODAETICA, 1995, 20 (06): : 475 - 488
  • [7] Quantum 3D FFT in Tomography
    Koukiou, Georgia
    Anastassopoulos, Vassilis
    APPLIED SCIENCES-BASEL, 2023, 13 (06):
  • [8] Convolution of 3D Gaussian surfaces for volumetric intensity inhomogeneity estimation and correction in 3D brain MR image data
    Kahali, Sayan
    Adhikari, Sudip Kumar
    Sing, Jamuna Kanta
    IET COMPUTER VISION, 2018, 12 (03) : 288 - 297
  • [9] Mechanism and implementation of error correction for 3D strata model
    Zhu Liang-feng
    Wu Xin-cai
    Pan Xin
    ROCK AND SOIL MECHANICS, 2006, 27 (02) : 268 - 271
  • [10] Implementation of 3D technologies in the workflow of auricular prosthetics: A method using optical scanning and stereolithography 3D printing
    Bannink, Tjitske
    Bouman, Shirley
    Wolterink, Rene
    van Veen, Robert
    van Alphen, Maarten
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (04): : 708 - 713