The study of thermal decomposition of RDX by corona discharge-ion mobility spectrometry-mass spectrometry

被引:3
作者
Lichvanova, Zuzana [1 ]
Sabo, Martin [1 ]
Matejcik, Stefan [1 ]
机构
[1] Comenius Univ, Fac Math Phys & Informat, Dept Expt Phys, Mlynska Dolina F2, Bratislava 84248, Slovakia
关键词
Corona discharge; Negative ions; Ion mobility spectrometry; Mass spectrometry; Thermal decomposition; RDX;
D O I
10.1007/s12127-015-0169-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this study we have examined the formation of ions from hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) sample evaporated at 473 K in reactions with reactant ions (RI) produced in negative corona discharge (CD). The ions have been analysed and detected by ion mobility spectrometry coupled to orthogonal acceleration time of flight spectrometer (IMS-oaTOF). The chemical ionisation was carried out by O-2(-), O-2(-) (H2O), N2O2-, N2O3- and N2O3- (H2O) RI formed in CD operated in zero air in the reverse gas flow mode at elevated temperatures 438 K and by Cl-(H2O) n (n= 0,1,2) at 332K. In case of 332K, theRIwere prepared by admixture of carbon tetrachloride (CCl4 - dopant gas) in order to enhance sensitivity of RDX.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [41] Identification of phase-II metabolites of flavonoids by liquid chromatography-ion-mobility spectrometry-mass spectrometry
    Chalet, Clement
    Hollebrands, Boudewijn
    Janssen, Hans-Gerd
    Augustijns, Patrick
    Duchateau, Guus
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (02) : 471 - 482
  • [42] Transport and stability of negative ions generated by negative corona discharge in air studied using ion mobility-oaTOF spectrometry
    Sabo, Martin
    Okuyama, Yui
    Kucera, Marek
    Matejcik, Stefan
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 334 : 19 - 26
  • [43] Ion mobility-mass spectrometry
    Kanu, Abu B.
    Dwivedi, Prabha
    Tam, Maggie
    Matz, Laura
    Hill, Herbert H., Jr.
    JOURNAL OF MASS SPECTROMETRY, 2008, 43 (01): : 1 - 22
  • [44] Study of field mobilities dependence and direct separation of acidic phytohormones by differential mobility spectrometry-mass spectrometry
    Pang, Nannan
    Yan, Cunyu
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2014, 362 : 48 - 55
  • [45] Comparison of reactant and analyte ions for 63Nickel, corona discharge, and secondary electrospray ionization sources with ion mobility-mass spectrometry
    Crawford, C. L.
    Hill, H. H.
    TALANTA, 2013, 107 : 225 - 232
  • [46] Reverse flow continuous corona discharge ionisation applied to ion mobility spectrometry
    Ross, SK
    Bell, AJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 218 (02) : L1 - L6
  • [47] Performance Enhancements in Differential Ion Mobility Spectrometry-Mass Spectrometry (DMS-MS) by Using a Modified CaptiveSpray Source
    Wu, Ri
    Wu, Wei-Jing
    Wang, Ze
    Wong, Y. -L. Elaine
    Hung, Y. -L. Winnie
    Wong, H. T.
    Chen, Xiangfeng
    Chan, T. -W. Dominic
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (11) : 2199 - 2207
  • [48] Effect of ionic wind on the sample distribution in corona discharge ion mobility spectrometry
    Wang, Jiyao
    Zhang, Chong
    Shi, Wenyan
    Ling, Yiyuan
    Wang, Xiaohao
    Ni, Kai
    TALANTA, 2025, 284
  • [49] Towards metals analysis using corona discharge ionization ion mobility spectrometry
    Jafari, Mohammad T.
    Saraji, Mohammad
    Sherafatmand, Hossein
    ANALYTICA CHIMICA ACTA, 2016, 909 : 84 - 90
  • [50] DETECTION OF TOLUENE, METHANOL AND FORMALDEHYDE USING CORONA DISCHARGE ION MOBILITY SPECTROMETRY
    Li, Shu
    Jia, Jian
    Gao, Xiaoguang
    He, Xiuli
    Li, Jianping
    ANALYTICAL LETTERS, 2012, 45 (08) : 841 - 849