Electrochemical Impedance Spectroscopic Sensing of Methamphetamine by a Specific Aptamer

被引:40
作者
Ebrahimi, Mohsen [1 ,2 ,3 ]
Johari-Ahar, Mohammad [3 ,4 ]
Hamzeiy, Hossein [1 ,3 ]
Barar, Jaleh [3 ,5 ]
Mashinchian, Omid [3 ]
Omidi, Yadollah [3 ,5 ]
机构
[1] Tabriz Univ Med Sci, Fac Pharm, Dept Toxicol & Pharmacol, Tabriz, Iran
[2] Tabriz Univ Med Sci, Students Res Comm, Tabriz, Iran
[3] Tabriz Univ Med Sci, Fac Pharm, Res Ctr Pharmaceut Nanotechnol, Tabriz, Iran
[4] Tabriz Univ Med Sci, Fac Pharm, Dept Med Chem, Tabriz, Iran
[5] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Aptamer; Electrochemical Impedance; Spectroscopy; Gold Nanoparticles; Biosensor;
D O I
10.5681/bi.2012.013
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Electrochemical impedance spectroscopy (EIS) is a simple and highly sensitive technique that can be used for evaluation of the aptamer-target interaction even in a label-free approach. Methods: To pursue the effectiveness of EIS, in the current study, the folding properties of specific aptamer for methamphetamine (METH) (i.e., aptaMETH) were evaluated in the presence of METH and amphetamine (Amph). Folded and unfolded aptaMETH was mounted on the gold electrode surface and the electron charge transfer was measured by EIS. Results: The Ret of methamphetamine-aptaMETH was significantly increased in comparison with other folding conditions, indicating specific detection of METH by aptaMETH. Conclusion: Based on these findings, methamphetamine-aptaMETH on the gold electrode surface displayed the most interfacial electrode resistance and thus the most folding situation. This clearly indicates that the aptaMETH can profoundly and specifically pinpoint METH; as a result we suggest utilization of this methodology for fast and cost-effective identification of METH.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 21 条
[11]   Aptamer biosensor for label-free impedance spectroscopy detection of thrombin based on gold nanoparticles [J].
Li, Li-Dong ;
Zhao, Hong-Tao ;
Chen, Zheng-Bo ;
Mu, Xiao-Jiao ;
Guo, Lin .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (01) :189-194
[12]   Electrochemical impedance spectroscopy for study of aptamer-thrombin interfacial interactions [J].
Li, Xiaoxia ;
Shen, Lihua ;
Zhang, Dongdong ;
Qi, Honglan ;
Gao, Qiang ;
Ma, Fen ;
Zhang, Chengxiao .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1624-1630
[13]  
Lupold SE, 2002, CANCER RES, V62, P4029
[14]   A sensitive and selective thrombin impedimetric aptasensor based on tailored aptamers obtained by solid-phase synthesis [J].
Meini, N. ;
Farre, C. ;
Chaix, C. ;
Kherrat, R. ;
Dzyadevych, S. ;
Jaffrezic-Renault, N. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 :715-720
[15]   Impedimetric aptasensor for thrombin detection [J].
Meini, N. ;
Farre, C. ;
Chaix, C. ;
Kherrat, K. ;
Dzyadevych, S. ;
Jaffrezic-Renault, N. .
EUROSENSORS XXV, 2011, 25
[16]   A sensitive nanoporous gold-based electrochemical aptasensor for thrombin detection [J].
Qiu, Huajun ;
Sun, Yanli ;
Huang, Xirong ;
Qu, Yinbo .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 79 (01) :304-308
[17]   Human immunodeficiency virus trans-activator of transcription peptide detection via ribonucleic acid aptamer on aminated diamond biosensor [J].
Ruslinda, A. Rahim ;
Wang, Xianfen ;
Ishii, Yoko ;
Ishiyama, Yuichiro ;
Tanabe, Kyosuke ;
Kawarada, Hiroshi .
APPLIED PHYSICS LETTERS, 2011, 99 (12)
[18]   Aptasensors for detection of microbial and viral pathogens [J].
Torres-Chavolla, Edith ;
Alocilja, Evangelyn C. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (11) :3175-3182
[19]   Au nanoparticle conjugation for impedance and capacitance signal amplification in biosensors [J].
Wang, JB ;
Profitt, JA ;
Pugia, MJ ;
Suni, II .
ANALYTICAL CHEMISTRY, 2006, 78 (06) :1769-1773
[20]  
Zhang DW, 2012, TALANTA, P9265