VOLTAMMETRY OF METALS AT MERCURY FILM MICROELECTRODES IN THE ABSENCE AND THE PRESENCE OF VARYING CONCENTRATIONS OF SUPPORTING ELECTROLYTE

被引:35
作者
CISZKOWSKA, M
OSTERYOUNG, JG
机构
[1] N CAROLINA STATE UNIV,DEPT CIVIL ENGN,RALEIGH,NC 27695
[2] UNIV WARSAW,DEPT CHEM,PL-02093 WARSAW,POLAND
关键词
D O I
10.1021/ac00102a017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The steady-state limiting current for reduction of mono- and divalent metal cations to amalgam in solution without supporting electrolyte depends on both the charge of the cation and the charge of the associated anion. The ratio of limiting current in the absence of supporting electrolyte (i(l) degrees) to diffusional current (i(d)) was found to agree well. with theoretical predictions (for reduction of M(+), 2 and 3/2 for X(-) and X(2-), respectively, and for M(2+), 3 and 2 for X(-) and X(2-), respectively). The reduction current of metal cation depends on the type and concentration of supporting electrolyte. The diffusional current is reached at a lower electrolyte ratio when the cation of the electrolyte is divalent than when it is monovalent. In solutions without supporting electrolyte, the limiting current for reduction of a cation having a large negative reduction potential was found to increase in the presence of a cation reducing at a less negative potential. This phenomenon was observed for thallium ion with hydrogen ion and for lead ion with hydrogen ion. The increase of the current is due to the increased rate of transport of the more easily reduced cation at potentials where both reductions are transport-controlled.
引用
收藏
页码:1125 / 1131
页数:7
相关论文
共 31 条
[11]   MICROELECTRODE STUDIES WITHOUT SUPPORTING ELECTROLYTE - MODEL AND EXPERIMENTAL COMPARISON FOR SINGLY AND MULTIPLY CHARGED IONS [J].
COOPER, JB ;
BOND, AM ;
OLDHAM, KB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 331 (1-2) :877-895
[12]   STRIPPING ANALYSIS AT MERCURY MICROELECTRODES IN THE ABSENCE OF SUPPORTING ELECTROLYTE [J].
DANIELE, S ;
MAZZOCCHIN, GA .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :3-11
[13]   PREPARATION AND PROPERTIES OF A MERCURY-PLATED IRIDIUM-BASED MICROELECTRODE [J].
DEVITRE, RR ;
TERCIER, ML ;
TSACOPOULOS, M ;
BUFFLE, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :419-425
[14]   DETERMINATION OF STABILITY-CONSTANTS USING A MERCURY MICROELECTRODE AND STEADY-STATE VOLTAMMETRY [J].
DOSSANTOS, MMC ;
GONCALVES, MLS .
ELECTROCHIMICA ACTA, 1992, 37 (08) :1413-1416
[15]  
Fleischmann M, 1987, ULTRAMICROELECTRODES
[16]   LINEAR SCAN VOLTAMMETRY AND CHRONOAMPEROMETRY AT SMALL MERCURY FILM ELECTRODES [J].
GALUS, Z ;
GOLAS, J ;
OSTERYOUNG, J .
ELECTROCHIMICA ACTA, 1987, 32 (04) :669-672
[17]   IRIDIUM-BASED SMALL MERCURY-ELECTRODES [J].
GOLAS, J ;
GALUS, Z ;
OSTERYOUNG, J .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :389-392
[18]  
Heyrovsky J., 1966, PRINCIPLES POLAROGRA
[19]   PSEUDOPOLAROGRAPHY AT THE MERCURY HEMISPHERE ULTRAMICROELECTRODE - THEORY AND EXPERIMENT [J].
KOUNAVES, SP .
ANALYTICAL CHEMISTRY, 1992, 64 (23) :2998-3003
[20]   ANALYTICAL UTILITY OF THE IRIDIUM-BASED MERCURY ULTRAMICROELECTRODE WITH SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY [J].
KOUNAVES, SP ;
DENG, W .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :375-379