CONTINUOUS SAMPLE PRETREATMENT USING A FREE-FLOW ELECTROPHORESIS DEVICE INTEGRATED ONTO A SILICON CHIP

被引:239
作者
RAYMOND, DE
MANZ, A
WIDMER, HM
机构
[1] Ciba-Geigy Ltd., Corporate Analytical Research
关键词
D O I
10.1021/ac00090a011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel concept for continuous sample pretreatment is presented. A planar silicon structure containing the channel system for free-flow electrophoresis has been fabricated using micromachining techniques. A separation bed (25 mu L volume), two arrays of 125 inlet and outlet channels, and two arrays of 2500 channels used to isolate the separation bed from the electrodes were integrated onto a silicon chip. Free-flow electrophoresis allows the separation of a mixture according to charge with the subsequent continuous collection of the sample band of interest. A continuous separation of rhodamine-B isothiocyanate labeled amino acids over a period of 20 min with an applied voltage of 50 V demonstrates the utility of this technique. The effect of flow from the side channel arrays, sample dilution, and the resolution as a function of the applied voltage is also presented.
引用
收藏
页码:2858 / 2865
页数:8
相关论文
共 34 条
[1]  
BOUSSE L, 1993, TRANSDUCERS 93, P916
[2]  
BURGGRAF N, 1993, HRC-J HIGH RES CHROM, V16, P594
[3]   CONDITIONS FOR PURIFICATION OF PROTEINS BY FREE-FLOW ZONE ELECTROPHORESIS [J].
CLIFTON, MJ ;
JOUVE, N ;
DEBALMANN, H ;
SANCHEZ, V .
ELECTROPHORESIS, 1990, 11 (11) :913-919
[4]   FLOW COUNTERBALANCED CAPILLARY ELECTROPHORESIS [J].
CULBERTSON, CT ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :955-962
[5]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[6]   FREE-FLOW ELECTROPHORESIS .3. ANALYTICAL VERSION FOR A RAPID, QUANTITATIVE-DETERMINATION OF ELECTROPHORETIC PARAMETERS [J].
HANNIG, K ;
WIRTH, H ;
SCHINDLER, RK ;
SPIEGEL, K .
HOPPE-SEYLERS ZEITSCHRIFT FUR PHYSIOLOGISCHE CHEMIE, 1977, 358 (07) :753-763
[7]   NEW ASPECTS IN PREPARATIVE AND ANALYTICAL CONTINUOUS FREE-FLOW CELL ELECTROPHORESIS [J].
HANNIG, K .
ELECTROPHORESIS, 1982, 3 (05) :235-243
[8]   FREE-FLOW ELECTROPHORESIS .1. THEORETICAL AND EXPERIMENTAL INVESTIGATIONS OF INFLUENCE OF MECHANICAL AND ELECTROKINETIC VARIABLES ON EFFICIENCY OF METHOD [J].
HANNIG, K ;
WIRTH, H ;
MEYER, BH ;
ZEILLER, K .
HOPPE-SEYLERS ZEITSCHRIFT FUR PHYSIOLOGISCHE CHEMIE, 1975, 356 (08) :1209-1223
[9]  
HANNING K, 1990, FREE FLOW ELECTROPHO
[10]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897