The Future of Continuous Glucose Monitoring: Closed Loop

被引:53
作者
Hovorka, Roman [1 ]
机构
[1] Univ Cambridge, Inst Med Sci, Cambridge CB2 0QQ, England
关键词
Automated insulin delivery; Artificial pancreas; Insulin pump; Control algorithm; Model-predictive control; PID control; Type; 1; diabetes;
D O I
10.2174/157339908785294479
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Improvements in accuracy of real-time continuous glucose monitoring facilitate the development of closed-loop systems consisting of a continuous glucose monitor, a control algorithm, and an insulin pump. Closedloop systems can be divided according to the way meal delivery is handled as "fully closed-loop" or "closed-loop" with meal announcement systems. Depending on the subcutaneous (sc) or intravenous (iv) body interface, three major types of closed-loop systems are recognised, (i) sc sensing and sc delivery system, (ii) the iv sensing and intraperitoneal delivery system, and (iii) the iv glucose sensing and iv insulin delivery system. Given the current research focus, this review centres on the sc-sc closed-loop approach, which has the greatest potential for a near-future commercial exploitation as recognised by the JDRF Artificial Pancreas Project. Other approaches utilising intraperitoneal or intravenous sensing/delivery are also discussed. Closed-loop systems may revolutionise diabetes management but their introduction is likely to be gradual starting from simpler applications such as hypoglycaemia prevention or overnight glucose control progressing to more complex approaches such as 24/7 glucose control. The most important question is what is achievable with existing technologies and when the first generation of closed-loop systems will find its way into clinical practice.
引用
收藏
页码:269 / 279
页数:11
相关论文
共 103 条
[1]   ARTIFICIAL ENDOCRINE PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W .
DIABETES, 1974, 23 (05) :389-396
[2]   Hypoglycemia in the diabetes control and complications trial [J].
不详 .
DIABETES, 1997, 46 (02) :271-286
[3]  
[Anonymous], 2007, RANDOMIZED STUDY REA
[4]  
[Anonymous], 2005, STANDARDS MED CAR S1, V28, pS4
[5]   Effects of age and sex on postprandial glucose metabolism - Differences in glucose turnover, insulin secretion, insulin action, and hepatic insulin extraction [J].
Basu, Rita ;
Man, Chiara Dalla ;
Campioni, Marco ;
Basu, Ananda ;
Klee, George ;
Toffolo, Gianna ;
Cobelli, Claudio ;
Rizza, Robert A. .
DIABETES, 2006, 55 (07) :2001-2014
[6]  
Belicar PS, 2003, DIABETES METAB, V29, P344
[7]   Glycemic control in the intensive care unit: Why we should wait for NICE-SUGAR [J].
Bellomo, R ;
Egi, M .
MAYO CLINIC PROCEEDINGS, 2005, 80 (12) :1546-1548
[8]  
Bequette B Wayne, 2005, Diabetes Technol Ther, V7, P28, DOI 10.1089/dia.2005.7.28
[9]   COMPUTER-SIMULATION OF PLASMA-INSULIN AND GLUCOSE DYNAMICS AFTER SUBCUTANEOUS INSULIN INJECTION [J].
BERGER, M ;
RODBARD, D .
DIABETES CARE, 1989, 12 (10) :725-736
[10]  
Bevier WC, 2007, DIABETES, V56, pA163