Delayed diagnosis of an intraorbital wooden foreign body

被引:3
作者
Bayramoglu, Sadik Etka [1 ]
Sayin, Nihat [1 ]
Erdogan, Mehmet [1 ]
Ekinci, Dilbade Yildiz [1 ]
Uzunlulu, Nail [2 ]
Bayramoglu, Zuhal [3 ]
机构
[1] Kanuni Sultan Suleyman Training & Res Hosp, Opthtalmol Dept Istanbul, Istanbul, Turkey
[2] Kanuni Sultan Suleyman Training & Res Hosp, Dept Radiol, Istanbul, Turkey
[3] Istanbul Univ, Dept Radiol, Istanbul Fac Med, Istanbul, Turkey
来源
ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY | 2018年 / 37卷 / 06期
关键词
Foreign body; orbita; trauma;
D O I
10.1080/01676830.2018.1440606
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A 35-year-old male patient was presented with pain on his right upper eyelid. A piece of wood injured his orbital and supraorbital regions while working at a furniture factory 10 days prior to our hospital admission. It was learned that the patient was discharged following the primary would closure procedure. Subsequent to the craniofacial computed tomography, primary wound closure was performed in the emergency room of previous hospital. In our clinic, a skin suturing on the nasal side of the right eyebrow was inspected and a foreign body (FB) was palpated on the superonasal contiguity of the patients' right globe. A hyperdense FB measuring 30x10x5mm in size with smooth margins on superonasal contour of the globe was detected. Superonasal orbitotomy was performed and the FB was completely removed. Finally, visual acuity was 20/20 and a mild residual ptosis was observed.
引用
收藏
页码:468 / 471
页数:4
相关论文
共 21 条
[1]   Comparison of the sensitivity for detecting foreign bodies among conventional plain radiography, computed tomography and ultrasonography [J].
Aras, M. H. ;
Miloglu, O. ;
Barutcugil, C. ;
Kantarci, M. ;
Ozcan, E. ;
Harorli, A. .
DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (02) :72-78
[2]   INTRAORBITAL WOOD FOREIGN-BODIES ON CT - USE OF WIDE BONE WINDOW SETTINGS TO DISTINGUISH WOOD FROM AIR [J].
DALLEY, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (02) :434-435
[3]   ORBITOCRANIAL WOODEN FOREIGN BODY: A PRE-, INTRA-, AND POSTOPERATIVE CHRONICLE: CASE REPORT [J].
Dunn, Ian F. ;
Kim, Dong H. ;
Rubin, Peter A. ;
Blinder, Russell ;
Gates, Jonathan ;
Golby, Alexandra J. .
NEUROSURGERY, 2009, 65 (02) :383-384
[4]   Projectile metallic foreign bodies in the orbit - A retrospective study of epidemiologic factors, management, and outcomes [J].
Finkelstein, M ;
Legmann, A ;
Rubin, PAD .
OPHTHALMOLOGY, 1997, 104 (01) :96-103
[5]   MAGNETIC-RESONANCE-IMAGING AND COMPUTED-TOMOGRAPHY IN A MODEL OF WOODEN FOREIGN-BODIES IN THE ORBIT [J].
GLATT, HJ ;
CUSTER, PL ;
BARRETT, L ;
SARTOR, K .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 6 (02) :108-114
[6]   Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes [J].
Lagalla, R ;
Manfrè, L ;
Caronia, A ;
Bencivinni, F ;
Duranti, C ;
Ponte, F .
EUROPEAN RADIOLOGY, 2000, 10 (08) :1338-1341
[7]   Clinical diagnosis and treatment of intraorbital wooden foreign bodies [J].
Li, Jia ;
Zhou, Li-Ping ;
Jin, Jing ;
Yuan, Hong-Feng .
CHINESE JOURNAL OF TRAUMATOLOGY, 2016, 19 (06) :322-325
[8]   Common Denominators in Retained Orbital Wooden Foreign Body [J].
Liu, Don .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 26 (06) :454-458
[9]  
McGuckin JF, 1996, AM J NEURORADIOL, V17, P129
[10]   An unexpected ferromagnetic foreign body detected during emergency magnetic resonance imaging: A case report [J].
Metterlein T. ;
Haubner F. ;
Knoppke B. ;
Graf B. ;
Zausig Y. .
BMC Research Notes, 7 (1)