THE INFLUENCE OF DOSE CONSTRAINT POINT PLACEMENT ON OPTIMIZED RADIATION-THERAPY TREATMENT PLANNING

被引:17
作者
MORRILL, SM
ROSEN, II
LANE, RG
BELLI, JA
机构
[1] Department of Radiation Therapy, The University of Texas Medical Branch, Galveston, TX
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 19卷 / 01期
关键词
Linear programming; Optimization; Quadratic programming; Radiation therapy; Treatment planning;
D O I
10.1016/0360-3016(90)90145-A
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To efficiently use linear and quadratic programming for treatment planning optimization on a routine basis, automated methods are needed for placing dose constraint points. We have investigated, for linear programming optimization, the minimum number of constraint points needed to achieve an acceptable approximation to the desired (ideal) solution. Seven different constraint point placement algorithms were evaluated for a given objective function. One of these algorithms was chosen for routine clinical use at our institution. This algorithm places constraint points on the perimeter of the target volume and on the perimeter and in the interior of each normal structure. Additional points are placed on the perimeter of a constant thickness buffer region surrounding the target volume. Excellent optimization results are obtained with 40-70 constraint points per treatment planning slice. © 1990.
引用
收藏
页码:129 / 141
页数:13
相关论文
共 16 条
  • [1] [Anonymous], 1986, NUMERICAL RECIPES
  • [2] METHOD OF LINEAR PROGRAMMING APPLIED TO RADIATION TREATMENT PLANNING
    BAHR, GK
    KEREIAKES, JG
    HORWITZ, H
    FINNEY, R
    GALVIN, J
    GOODE, K
    [J]. RADIOLOGY, 1968, 91 (04) : 686 - +
  • [3] CUNNINGHAM J R, 1972, Computer Programs in Biomedicine, V2, P192, DOI 10.1016/0010-468X(72)90029-3
  • [4] SCATTER-AIR RATIOS
    CUNNINGHAM, JR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (01) : 42 - +
  • [5] SEMIAUTOMATIC OPTIMIZATION OF EXTERNAL BEAM RADIATION TREATMENT PLANNING
    HODES, L
    [J]. RADIOLOGY, 1974, 110 (01) : 191 - 196
  • [6] OPTIMIZATION OF X-RAY TREATMENT PLANNING BY COMPUTER JUDGEMENT
    HOPE, CS
    LAURIE, J
    ORR, JS
    HALNAN, KE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1967, 12 (04) : 531 - &
  • [7] OPTIMIZATION OF BEAM WEIGHTS UNDER DOSE-VOLUME RESTRICTIONS
    LANGER, M
    LEONG, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (08): : 1255 - 1260
  • [8] LASDON L, 1970, OPTIMIZATION THEORY, P20
  • [9] SOFTWARE FOR LINEAR AND NON-LINEAR OPTIMIZATION IN EXTERNAL RADIOTHERAPY
    LEGRAS, J
    LEGRAS, B
    LAMBERT, JP
    [J]. COMPUTER PROGRAMS IN BIOMEDICINE, 1982, 15 (03): : 233 - 242
  • [10] AUTOMATIC VARIATION OF FIELD SIZE AND DOSE-RATE IN ROTATION THERAPY
    MANTEL, J
    PERRY, H
    WEINKAM, JJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (7-8): : 697 - 704