ASSESSMENT OF THE DENTATE ALVEOLAR PROCESS WITH HIGH-RESOLUTION COMPUTED-TOMOGRAPHY

被引:66
|
作者
FUHRMANN, RAW
WEHRBEIN, H
LANGEN, HJ
DIEDRICH, PR
机构
[1] Department of Orthodontics, Medical Faculty, Aachen
[2] Department of Diagnostic Radiology, Medical Faculty, Aachen
关键词
TOMOGRAPHY; X-RAY COMPUTED; ALVEOLAR PROCESS; PERIODONTAL DISEASES; RADIOGRAPHY; DENTAL;
D O I
10.1259/dmfr.24.1.8593909
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The present study was undertaken to determine quantitatively the accuracy of modern high-resolution computed tomography (HR-CT) in imaging periodontal defects in vitro by means of comparative radiological and histological studies. The soft tissue and metallic restorations were removed from four mandibular and maxillary jaw segments. Eighteen lingual and buccal defects of different dimensions were artificially created over the roots of the teeth. Dental radiographs and 1.0 mm contiguous axial and coronal HR-CT scans were obtained. Histological specimens were prepared in the same plane as the CT scans. A quantitative analysis of the periodontal regions on the CT scans was feasible when the alveolar bone was 0.5 mm thick. A visible periodontal ligament space was found to improve the reliability of the measurement of buccal or lingual bone plates up to 0.2 mm thick or of the artificial dehiscences. In the axial HR-CT scans, 70% of the artificial defects could be identified, and in the coronal scans, 50%. In contrast, none of the defects could be evaluated on conventional dental radiographs. It is concluded that HR-CT scanning could be useful in assessing buccal and lingual alveolar bone morphology and in diagnosing larger dehiscences.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 50 条
  • [31] High resolution muon computed tomography at neutrino beam facilities
    Suerfu, B.
    Tully, C. G.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [32] Correlation between high-resolution computed tomography appearance and histopathological features in the diagnosis of interstitial lung diseases. A real-life study
    Lyberis, Paraskevas
    Verri, Giulia
    Solidoro, Paolo
    Femia, Federico
    Perotti, Costanza
    Limerutti, Giorgio
    Delsedime, Luisa
    Della Beffa, Eleonora
    Papotti, Mauro G.
    Ruffini, Enrico
    Albera, Carlo
    Guerrera, Francesco
    MINERVA SURGERY, 2024, 79 (02): : 133 - 139
  • [33] Pulmonary changes on high-resolution computed tomography of patients with rheumatoid arthritis and their association with clinical, demographic, serological and therapeutic variables
    Skare, Thelma Larocca
    Nakano, Irene
    Escuissiato, Dante Luiz
    Batistetti, Renato
    Rodrigues, Tales de Oliveira
    Silva, Marilia Barreto
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2011, 51 (04) : 325 - 337
  • [34] Detecting new erosions in rheumatoid arthritis over one year - Radiography and high-resolution computed tomography of finger joints
    Therkildsen, Josephine
    Klose-Jensen, Rasmus
    Hanel, Mathias
    Langdahl, Bente L.
    Thomsen, Jesper S.
    Manske, Sarah L.
    Keller, Kresten K.
    Hauge, Ellen-Margrethe
    JOINT BONE SPINE, 2025, 92 (01)
  • [35] QUANTITATIVE ASSESSMENT OF CEREBRAL BLOOD-VOLUME BY SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    SABATINI, U
    CELSIS, P
    VIALLARD, G
    RASCOL, A
    MARCVERGNES, JP
    STROKE, 1991, 22 (03) : 324 - 330
  • [36] Localized prior knowledge and optimal interpolation in high-resolution tomography
    Willis, AJ
    Jager, M
    Eggers, J
    Koch, RDM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (04) : 538 - 541
  • [37] Radiomics of high-resolution computed tomography for the differentiation between cholesteatoma and middle ear inflammation: effects of post-reconstruction methods in a dual-center study
    Arendt, Christophe T.
    Leithner, Doris
    Mayerhoefer, Marius E.
    Gibbs, Peter
    Czerny, Christian
    Arnoldner, Christoph
    Burck, Iris
    Leinung, Martin
    Tanyildizi, Yasemin
    Lenga, Lukas
    Martin, Simon S.
    Vogl, Thomas J.
    Schernthaner, Ruediger E.
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 4071 - 4078
  • [38] Segmentation and quantification of bone erosions in high-resolution peripheral quantitative computed tomography datasets of the metacarpophalangeal joints of patients with rheumatoid arthritis
    Toepfer, Dominique
    Finzel, Stephanie
    Museyko, Oleg
    Schett, Georg
    Engelke, Klaus
    RHEUMATOLOGY, 2014, 53 (01) : 65 - 71
  • [39] A COMPARISON OF RADIOGRAPHY, COMPUTED-TOMOGRAPHY, AND MAGNETIC-RESONANCE-IMAGING FOR THE DIAGNOSIS OF PALMAR PROCESS FRACTURES IN FOALS
    KANEPS, AJ
    KOBLIK, PD
    FREEMAN, DM
    POOL, RR
    OBRIEN, TR
    VETERINARY RADIOLOGY & ULTRASOUND, 1995, 36 (06) : 467 - 477
  • [40] The SPECTRA Collaboration OMERACT Working Group: Construct Validity of Joint Space Outcomes with High-resolution Peripheral Quantitative Computed Tomography
    Manske, Sarah L.
    Brunet, Scott C.
    Finzel, Stephanie
    Stok, Kathryn S.
    Conaghan, Philip G.
    Boyd, Steven K.
    Barnabe, Cheryl
    JOURNAL OF RHEUMATOLOGY, 2019, 46 (10) : 1369 - 1373