Inadvertent Screw Stripping During Ankle Fracture Fixation in Elderly Bone

被引:32
作者
Dinah, A. Feroz [1 ]
Mears, Simon C. [1 ]
Knight, Trevor A. [1 ]
Soin, Sandeep P. [1 ]
Campbell, John T. [2 ]
Belkoff, Stephen M. [1 ]
机构
[1] Johns Hopkins Univ, Johns Hopkins Bayview Med Ctr, Int Ctr Orthopaed Adv, Dept Orthopaed Surg, Baltimore, MD 21224 USA
[2] Mercy Med Ctr, Inst Foot & Ankle Reconstruct, Baltimore, MD 21210 USA
关键词
insertion torque; stripping torque; bone density; inadvertent stripping; ankle fracture;
D O I
10.1177/2151458511401352
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Poor screw purchase because of osteoporosis presents difficulties in ankle fracture fixation. The aim of our study was to determine if cortical thickness, unicortical versus bicortical purchase, and bone mineral density are predictors of inadvertent screw stripping and overtightening. Ten paired cadaver ankles (average donor age, 81.7 years; range, 50-97 years) were used for the study. Computed tomography scanning with phantoms of known density was used to determine the bone density along the distal fibula. A standard small-fragment, 7-hole, one-third tubular plate was applied to the lateral surface of the fibula, with 3 proximal bicortical cortical screws and 2 distal unicortical cancellous screws. A posterior plate, in which all 5 screws were cortical and achieved bicortical purchase, was subsequently applied to the same bones and positioned so that the screw holes did not overlap. A torque sensor was used to measure the torque of each screw during insertion (T i) and then stripping (Ts). The effect of bone density, screw location, cortical thickness, and unicortical versus bicortical purchase on Ti and Ts was checked for significance (P <.05) using a general linearized latent and mixed model. We found that 9% of the screws were inadvertently stripped and 12% were overtightened. Despite 21% of the screws being stripped or being at risk for stripping, we found no significant predictors to warn of impending screw stripping. Additional work is needed to identify clinically useful predictors of screw stripping.
引用
收藏
页码:86 / 89
页数:4
相关论文
共 13 条
[1]   Use of a synthetic bone void filler to augment screws in osteopenic ankle fracture fixation [J].
Andreassen, GS ;
Hoiness, PR ;
Skraamm, I ;
Granlund, O ;
Engebretsen, L .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (03) :161-165
[2]  
Black J., 1982, NATURAL LIVING RELAT, P5
[3]   Moments and forces during pedicle screw insertion -: In vitro and in vivo measurements [J].
Bühler, DW ;
Berlemann, U ;
Oxland, TR ;
Nolte, LP .
SPINE, 1998, 23 (11) :1220-1227
[4]   Factors affecting the pullout strength of cancellous bone screws [J].
Chapman, JR ;
Harrington, RM ;
Lee, KM ;
Anderson, PA ;
Tencer, AF ;
Kowalski, D .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :391-398
[5]   Effect of screw torque level on cortical bone pullout strength [J].
Cleek, Tammy M. ;
Reynolds, Karen J. ;
Hearn, Trevor C. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (02) :117-123
[6]   Effects of surgical errors on small fragment screw fixation [J].
Collinge, Cory ;
Hartigan, Brian ;
Lautenschlager, Eugene P. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (06) :410-413
[7]  
Cordey J., 1980, CURRENT CONCEPTS INT, P235
[9]   Effect of bone mineral density and amorphous diamond coatings on insertion torque of bone screws [J].
Koistinen, A ;
Santavirta, SS ;
Kröger, H ;
Lappalainen, R .
BIOMATERIALS, 2005, 26 (28) :5687-5694
[10]  
ROBBINS SL, 1984, PATHOLOGIC BASIS DIS, P1