ACCURACY AND REPRODUCIBILITY OF INSTRUMENTED KNEE-DRAWER TESTS

被引:47
作者
EDIXHOVEN, P
HUISKES, R
DEGRAAF, R
VANRENS, TJG
SLOOFF, TJ
机构
[1] CATHOLIC UNIV NIJMEGEN,DEPT ORTHOPAED,EXPTL ORTHOPAED LAB,POB 9101,6500 HB NIJMEGEN,NETHERLANDS
[2] CATHOLIC UNIV NIJMEGEN,DEPT MATH & STAT,6500 HB NIJMEGEN,NETHERLANDS
关键词
BIOLOGICAL MATERIALS - Ligaments - BIOMECHANICS - Joints;
D O I
10.1002/jor.1100050310
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The effects of several parameters on the accuracy and reproducibility of anterior-posterior (AP) drawer measurements were investigated. An instrumented knee-drawer tester for AP laxity evaluations was constructed, based on the differential displacement method, measuring shifts of the tuberosity relative to the patella. The accuracy of the AP-shift was determined with the parallel use of a highly accurate roentgen stereo photogrammetric (RSP) measurement system on two postmortem leg specimens. The effects of relative motion between patella and femur were negligible. In addition to AP shifts, significant knee flexion and tibial rotations occurred. Tests were made to evaluate the effects of different observers, time sequences, and different days. In addition, effects of muscle relaxation were studied. Overall, the shift parameters at different forces were found to be reproducible to between 5 and 15%. The slopes (compliances) of the laxity curves, at different forces, were found to be reproducible to between 20 and 40%. The reproducibility was principally affected by deviations in the subject positioning procedure.
引用
收藏
页码:378 / 387
页数:10
相关论文
共 20 条
[1]  
BLANKEVOORT L, 1986, 32ND T ANN ORTH RES
[2]  
BROMAGE PR, 1978, EPIDURAL ANALGESIA
[3]   LIGAMENTOUS RESTRAINTS TO ANTERIOR-POSTERIOR DRAWER IN THE HUMAN KNEE - BIOMECHANICAL STUDY [J].
BUTLER, DL ;
NOYES, FR ;
GROOD, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (02) :259-270
[4]   INSTRUMENTED MEASUREMENT OF ANTERIOR LAXITY OF THE KNEE [J].
DANIEL, DM ;
MALCOM, LL ;
LOSSE, G ;
STONE, ML ;
SACHS, R ;
BURKS, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (05) :720-726
[5]   KINEMATIC BEHAVIOR OF THE HUMAN WRIST JOINT - A ROENTGEN-STEREOPHOTOGRAMMETRIC ANALYSIS [J].
DELANGE, A ;
KAUER, JMG ;
HUISKES, R .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (01) :56-64
[6]   AN INVITRO BIOMECHANICAL EVALUATION OF ANTERIOR-POSTERIOR MOTION OF THE KNEE - TIBIAL DISPLACEMENT, ROTATION, AND TORQUE [J].
FUKUBAYASHI, T ;
TORZILLI, PA ;
SHERMAN, MF ;
WARREN, RF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (02) :258-264
[7]   STABILIZING MECHANISMS OF LOADED AND UNLOADED KNEE-JOINT [J].
HSIEH, HH ;
WALKER, PS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) :87-93
[8]  
Huiskes R., 1985, Biomechanics of Normal and Pathological Human Articulating Joints. Proceedings of the NATO Advanced Study Institute, P165
[9]  
JACOBSON K, 1981, ACTA ORTHOP SCAND S, V194
[10]   MEDIAL AND ANTERIOR INSTABILITY OF KNEE - ANATOMICAL AND CLINICAL STUDY USING STRESS MACHINES [J].
KENNEDY, JC ;
FOWLER, PJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (07) :1257-&