Abdominal Applications of a Novel Detector-Based Spectral CT

被引:25
|
作者
Fulton, Nicholas [1 ]
Rajiah, Prabhakar [2 ]
机构
[1] Univ Hosp Cleveland Med Ctr, Dept Radiol, Cleveland, OH USA
[2] UT Southwestern Med Ctr, Dept Radiol, Cardiothorac Imaging, Dallas, TX 75390 USA
关键词
D O I
10.1067/j.cpradiol.2017.05.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Detector-based spectral computed tomography (SDCT) is a recently introduced technology that uses a single x-ray tube and 2 layers of detectors to simultaneously collect low- and high-energy data. In this article, we provide an overview of this novel SDCT technology in abdominal imaging. Several applications of SDCT in abdominal imaging are discussed and illustrated, along with a brief description of current literature on the status of dual-energy computed tomography in these applications. This includes urinary calculus composition, characterization of masses (renal, adrenal, hepatic, and others), tumor perfusion, improving vascular contrast, improving lesion conspicuity, decreasing artifacts, and reducing radiation dose. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 50 条
  • [21] Development of a detector-based absolute spectral irradiance scale in the 380-900-nm spectral range
    Karha, P
    Toivanen, P
    Manoochehri, F
    Ikonen, E
    APPLIED OPTICS, 1997, 36 (34) : 8909 - 8918
  • [22] Evaluation of virtual non-contrast detector-based spectral CT images in comparison to true unenhanced images in 20 rabbits
    Mikic, Manon
    Lietz, Philipp
    Dierig, Julie-Ann
    Meller, Sebastian
    Pees, Michael
    Merhof, Kristina
    FRONTIERS IN VETERINARY SCIENCE, 2025, 12
  • [23] Development of a detector-based absolute spectral power responsivity scale in the spectral range of 300–1600 nm
    Abdallah M. Karmalawi
    Alaaeldin A. Abdelmageed
    Journal of Materials Science: Materials in Electronics, 2021, 32 : 5215 - 5221
  • [24] Development of a detector-based absolute spectral irradiance scale in the 380-900-nm spectral range
    Metrology Research Institute, Helsinki University of Technology, P.O. Box 3000, FIN-02015 HUT, Finland
    Applied Optics, 1997, 36 (34): : 8909 - 8918
  • [25] Spectral detector CT applications in advanced liver imaging
    Majeed, Noor Fatima
    Amirfarzan, Marta Braschi
    Wald, Christoph
    Wortman, Jeremy R.
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1123):
  • [26] Flat panel detector-based cone-beam volume CT breast imaging: detector evaluation
    Yu, Y
    Conover, D
    Ning, RL
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 711 - 719
  • [28] New data-reduction method in detector-based spectral-irradiance measurements
    Andor, G
    METROLOGIA, 1996, 32 (06) : 495 - 496
  • [29] Development of a detector-based absolute spectral power responsivity scale in the spectral range of 300-1600 nm
    Karmalawi, Abdallah M.
    Abdelmageed, Alaaeldin A.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2021, 32 (04) : 5215 - 5221
  • [30] Flat panel detector-based cone beam CT imaging: Preliminary system evaluation
    Ning, RL
    Conover, D
    Yu, Y
    Lu, XH
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 616 - 620