A HISTOMORPHOMETRIC EVALUATION OF BONE-TO-IMPLANT CONTACT ON MACHINE-PREPARED AND ROUGHENED TITANIUM DENTAL IMPLANTS - A PILOT-STUDY IN THE DOG

被引:117
作者
ERICSSON, I
JOHANSSON, CB
BYSTEDT, H
NORTON, MR
机构
[1] GOTHENBURG UNIV, DEPT HANDICAP RES, S-41390 GOTHENBURG, SWEDEN
[2] SABBATSBERGS HOSP, DEPT ORAL & MAXILLOFACIAL SURG, STOCKHOLM, SWEDEN
[3] ASTRA TECH AB, MOLNDAL, SWEDEN
关键词
DOG; HISTOMORPHOMETRY; IMPLANT; COMMERCIALLY PURE TITANIUM; TITANIUM DIOXIDE;
D O I
10.1034/j.1600-0501.1994.050402.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This investigation was performed to assess the bone-to-implant surface contact at fixtures of titanium that either had a standard machine prepared or a TiO2-blasted surface. Five beagle dogs were used in the experiment. Extractions of the premolars were performed in the maxilla. After 4 months of healing, 5 standard machine-prepared fixtures and 5 prepared according to the TioBlast technique were inserted. Two months later another 5 ''standard'' and 5 TioBlast-prepared implants were inserted. Four months after the first fixture installation, the animals were killed and ground sections prepared from each implant site. Of the 20 implants installed, 19 were successfully incorporated. The mean bone-to-implant surface for ''standard'' fixtures was about 40% both at the 2 and 4 months observation interval. The corresponding figures for the TioBlast-prepared fixtures were similar during the first 2 months of observation, while subsequently the TioBlast-prepared fixture surface seemed to stimulate to a mon close bone-to-implant contact (65%) than the ''standard'' one.
引用
收藏
页码:202 / 206
页数:5
相关论文
共 23 条
  • [1] ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
  • [2] Adell R, 1985, TISSUE INTEGRATED PR
  • [3] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [4] Arvidson K, 1992, Int J Oral Maxillofac Implants, V7, P321
  • [5] INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS
    BUSER, D
    SCHENK, RK
    STEINEMANN, S
    FIORELLINI, JP
    FOX, CH
    STICH, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07): : 889 - 902
  • [6] BONE RESPONSE TO HYDROXYAPATITE-COATED AND COMMERCIALLY PURE TITANIUM IMPLANTS IN THE HUMAN ARTHRITIC KNEE
    CARLSSON, L
    REGNER, L
    JOHANSSON, C
    GOTTLANDER, M
    HERBERTS, P
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (02) : 274 - 285
  • [7] CARLSSON L, 1989, THESIS U GOTEBORG GO
  • [8] A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE
    DONATH, K
    BREUNER, G
    [J]. JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) : 318 - 326
  • [9] Donath K., 1988, PRAPARATOR, V34, P197
  • [10] A CLINICAL-EVALUATION OF FIXED-BRIDGE RESTORATIONS SUPPORTED BY THE COMBINATION OF TEETH AND OSSEOINTEGRATED TITANIUM IMPLANTS
    ERICSSON, I
    LEKHOLM, U
    BRANEMARK, PI
    LINDHE, J
    GLANTZ, PO
    NYMAN, S
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1986, 13 (04) : 307 - 312