MODEL ANALYSIS OF THE DETERMINATION OF THE MARK-HOUWINK-KUHN-SAKURADA PARAMETERS AND MOLECULAR-WEIGHT DISTRIBUTION BY MEANS OF SIZE-EXCLUSION CHROMATOGRAPHY WITH DUAL DETECTION

被引:13
作者
NETOPILIK, M
机构
[1] Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic
关键词
SIZE EXCLUSION CHROMATOGRAPHY; DUAL DETECTION; MOLECULAR WEIGHT DISTRIBUTION;
D O I
10.1016/0032-3861(94)90735-8
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The analysis of a polymer obeying the log-normal molecular weight distribution (MWD) by means of size exclusion chromatography with dual concentration/light scattering or viscosity detection was theoretically examined. The relations between the theoretical and experimental values of MWD parameters and Mark-Houwink-Kuhn-Sakurada constants calculated by comparing viscometric, light scattering and effective linear calibrations to the universal one were calculated as functions of the instrument parameters (interdetector volume and resolution factor). The linearity of calibrations calculated from the dual trace directly or indirectly, by combining with the universal calibration, is preserved.
引用
收藏
页码:4799 / 4803
页数:5
相关论文
共 23 条
[1]   GEL PERMEATION CHROMATOGRAMS - APPROXIMATE RELATION OF LINE SHAPE TO POLYMER POLYDISPERSITY [J].
BERGER, HL ;
SHULTZ, AR .
JOURNAL OF POLYMER SCIENCE PART A-GENERAL PAPERS, 1965, 3 (10PA) :3643-&
[2]   DATA INTERPRETATION FOR COUPLED MOLECULAR-WEIGHT SENSITIVE DETECTORS IN SEC - INTERDETECTOR TRANSPORT TIME [J].
CHEUNG, P ;
BALKE, ST ;
MOUREY, TH .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (01) :39-69
[3]   SEC-VISCOMETER DETECTOR SYSTEMS .2. RESOLUTION CORRECTION AND DETERMINATION OF INTERDETECTOR VOLUME [J].
CHEUNG, P ;
LEW, R ;
BALKE, ST ;
MOUREY, TH .
JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 47 (09) :1701-1706
[4]   USE OF BROAD DISTRIBUTION POLYMERS AND GPC METHODS FOR ESTIMATION OF MARK-HOUWINK-SAKURADA CONSTANTS [J].
DOBBIN, CJB ;
RUDIN, A ;
TCHIR, MF .
JOURNAL OF APPLIED POLYMER SCIENCE, 1982, 27 (03) :1081-1085
[5]   A UNIVERSAL CALIBRATION FOR GEL PERMEATION CHROMATOGRAPHY [J].
GRUBISIC, Z ;
REMPP, P ;
BENOIT, H .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER LETTERS, 1967, 5 (9PB) :753-&
[6]   COMPUTER-SIMULATION STUDY OF SIZE-EXCLUSION CHROMATOGRAPHY WITH SIMULTANEOUS VISCOMETRY AND LIGHT-SCATTERING MEASUREMENTS [J].
JACKSON, C ;
YAU, WW .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (02) :209-217
[7]   EVALUATION OF LIGHT-SCATTERING DETECTORS FOR SIZE-EXCLUSION CHROMATOGRAPHY .1. INSTRUMENT PRECISION AND ACCURACY [J].
JENG, L ;
BALKE, ST ;
MOUREY, TH ;
WHEELER, L ;
ROMEO, P .
JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 49 (08) :1359-1374
[8]   EVALUATION OF LIGHT-SCATTERING DETECTORS FOR SIZE-EXCLUSION CHROMATOGRAPHY .2. LIGHT-SCATTERING EQUATION SELECTION [J].
JENG, L ;
BALKE, ST .
JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 49 (08) :1375-1385
[9]  
KOTLIAR AM, 1964, J POLYM SCI PART A, V2, P4303, DOI 10.1002/pol.1964.100021005
[10]   SEC-VISCOMETER DETECTOR SYSTEMS .1. CALIBRATION AND DETERMINATION OF MARK-HOUWINK CONSTANTS [J].
LEW, R ;
CHEUNG, P ;
BALKE, ST ;
MOUREY, TH .
JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 47 (09) :1685-1700