SYNTHESIS AND USE OF QUATERNIZED POLYETHYLENIMINE-COATED ZIRCONIA FOR HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY

被引:22
作者
MCNEFF, C [1 ]
CARR, PW [1 ]
机构
[1] UNIV MINNESOTA,DEPT CHEM,MINNEAPOLIS,MN 55455
关键词
D O I
10.1021/ac00117a011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The synthesis of an alkali-stable strong anion-exchange stationary phase by deposition of polyethylenimine (PEI), followed by cross-linking and quaternization, onto porous zirconia particles is described. Physical characterization of quaternized PEI-zirconia and PEI-zirconia shows that 50% and 24% of the amine groups are cross-linked, respectively. A plot of log k' versus log (competing ion concentration) is linear for three homopeptides, suggesting that ion exchange is the primary mechanism of retention on quaternized PEI-zirconia. Column efficiency for two 2,4-dinitrophenyl amino acids increased by 80% upon increasing the temperature from 50 degrees C to 100 degrees C. The hydrophobicity of quaternized PEI-zirconia was studied using a homologous series of p-alkoxybenzoic acids, For quaternized PEI-zirconia and PEI-zirconia, we found that the free energy of transfer of a methylene unit from the mobile phase to the stationary phase was -2.0 and -0.90 kJ/mol, respectively. The free energy of transfer of a methylene unit on quaternized PEI-zirconia is similar to that of a typical ODS phase (-2.4 kJ/mol). A van't Hoff plot for the above two 2,4-dinitrophenyl amino acids showed that the enthalpies of transfer are exothermic and fairly large (similar to -14 kJ/mol). Isocratic separations on quaternized PEI-zirconia of inorganic and organic anions are presented. Quaternized PEI-zirconia, quaternary amine-functionalized silica, and PEI-zirconia are compared chromatographically. Quaternized PEI-zirconia is more efficient than the silica-based phase in the separation of benzoic acid derivatives but slightly less efficient than PEI-zirconia. The major virtue of quaternized PEI-zirconia is that it is chemically stable in the pH range of 1-13 and is also stable at temperatures up to 100 degrees C.
引用
收藏
页码:3886 / 3892
页数:7
相关论文
共 39 条
[1]  
ANDREW AJ, 1979, J CHROMATOGR, V185, P375
[2]   BEADED POLYMER SUPPORTS AND GELS .2. PHYSICOCHEMICAL CRITERIA AND FUNCTIONALIZATION [J].
ARSHADY, R .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (02) :199-219
[3]  
BLACKWELL JA, 1991, THESIS U MINNESOTA M
[4]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[5]   SOLVATOCHROMISM, LINEAR SOLVATION ENERGY RELATIONSHIPS, AND CHROMATOGRAPHY [J].
CARR, PW .
MICROCHEMICAL JOURNAL, 1993, 48 (01) :4-28
[6]  
CHICZ RM, 1986, J CHROMATOGR, V339, P121
[7]   ROLE OF THE TEMPERATURE IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PYROCARBON-CONTAINING ADSORBENTS [J].
COLIN, H ;
DIEZMASA, JC ;
GUIOCHON, G ;
CZAJKOWSKA, T ;
MIEDZIAK, I .
JOURNAL OF CHROMATOGRAPHY, 1978, 167 (DEC) :41-65
[8]   HIGH-PERFORMANCE ANION-EXCHANGE CHROMATOGRAPHY OF OLIGONUCLEOTIDES [J].
DRAGER, RR ;
REGNIER, FE .
ANALYTICAL BIOCHEMISTRY, 1985, 145 (01) :47-56
[9]   ANION CHROMATOGRAPHY WITH LOW-CONDUCTIVITY ELUENTS [J].
GJERDE, DT ;
FRITZ, JS ;
SCHMUCKLER, G .
JOURNAL OF CHROMATOGRAPHY, 1979, 186 (DEC) :509-519
[10]   ANION CHROMATOGRAPHY WITH LOW-CONDUCTIVITY ELUENTS .2. [J].
GJERDE, DT ;
SCHMUCKLER, G ;
FRITZ, JS .
JOURNAL OF CHROMATOGRAPHY, 1980, 187 (01) :35-45