COMPARISON OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, SUPERCRITICAL FLUID CHROMATOGRAPHY AND CAPILLARY ZONE ELECTROPHORESIS IN DRUG ANALYSIS

被引:74
作者
STEUER, W
GRANT, I
ERNI, F
机构
[1] Analytical Research and Development, Pharma Division, Sandoz Ltd., Basle
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 507卷
关键词
D O I
10.1016/S0021-9673(01)84188-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-performance liquid chromatography (HPLC), supercritical fluid chromatography (SFC) and capillary zone electrophoresis (CZE) are compared with respect to their usefulness in drug analysis. Factors discussed include efficinecy, performance, sensitivity, optimization parameters, method development time, sample preparation, technical difficulties, orthogonality of the information obtained and the possible application to various substance groups. It is concluded that HPLC can be applied successfully in virtually all areas of pharmaceutical analysis. CZE has a promising future in the analysis of drugs and in the field of biotechnological analysis, where a high number of plates is required together with short analysis time. Nevertheless improvements in detection are still necessary for most applications. SFC is particularly suitable for moderately polar compounds or substances for which mass-sensitive detection is required. SFC and CZE can be considered as complementary to HPLC owing to the orthogonality of the acquired data, and as a result more information can be obtained from the analysis. © 1990.
引用
收藏
页码:125 / 140
页数:16
相关论文
共 26 条
[1]  
ANTIA FD, 1988, J CHROMATOGR, V435, P1
[2]  
BEYER TA, 1989, J CHROMATOGR SCI, V27, P105
[3]  
DAVIS JM, 1983, ANAL CHEM, V55, P418, DOI 10.1021/ac00254a003
[4]   AUTOMATION AND VALIDATION OF HPLC-SYSTEMS [J].
ERNI, F ;
STEUER, W ;
BOSSHARDT, H .
CHROMATOGRAPHIA, 1987, 24 :201-207
[5]   2-DIMENSIONAL COLUMN LIQUID-CHROMATOGRAPHIC TECHNIQUE FOR RESOLUTION OF COMPLEX-MIXTURES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :561-569
[6]   EFFECT OF ADDITION OF ORGANIC-SOLVENT ON THE SEPARATION OF POSITIONAL ISOMERS IN HIGH-VOLTAGE CAPILLARY ZONE ELECTROPHORESIS [J].
FUJIWARA, S ;
HONDA, S .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :487-490
[7]   BIAS IN QUANTITATIVE CAPILLARY ZONE ELECTROPHORESIS CAUSED BY ELECTROKINETIC SAMPLE INJECTION [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (04) :375-377
[8]  
HUBER JFK, 1979, J CHROMATOGR, V172, P15, DOI 10.1016/S0021-9673(00)90941-5
[9]   SEPARATION OF OPIUM-ALKALOIDS BY CARBON-DIOXIDE SUBCRITICAL AND SUPERCRITICAL FLUID CHROMATOGRAPHY WITH PACKED-COLUMNS - APPLICATION TO THE QUANTITATIVE-ANALYSIS OF POPPY STRAW EXTRACTS [J].
JANICOT, JL ;
CAUDE, M ;
ROSSET, R .
JOURNAL OF CHROMATOGRAPHY, 1988, 437 (02) :351-364
[10]   HIGH-RESOLUTION SEPARATIONS BASED ON ELECTROPHORESIS AND ELECTROOSMOSIS [J].
JORGENSON, JW ;
LUKACS, KD .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :209-216