PREDICTION OF NIPPLE VIABILITY FOLLOWING REDUCTION MAMMAPALSTY USING LASER DOPPLER FLOWMETRY

被引:5
作者
HALLOCK, GG [1 ]
机构
[1] DOROTHY RIDER POOL MICROSURG & LASER LAB,ALLENTOWN,PA
关键词
D O I
10.1097/00000637-199211000-00016
中图分类号
R61 [外科手术学];
学科分类号
摘要
The assessment of viability of a pedicled nipple-areola complex after reduction mammoplasty frequently may be frustrating due to equivocal clinical signs of adequate blood flow. Although conversion to a composite graft is always a safe option, the aesthetic result may be inferior. An objective monitor might be beneficial to maximize the surgical outcome while minimizing the risk of nipple necrosis. Laser Doppler flowmetry provides a safe, simple, and noninvasive objective monitor that allows continuous intraoperative or postoperative evaluation of nipple perfusion. An evaluation of 31 nipples in 16 patients undergoing breast reduction based solely on the surgeon's judgment would have resulted in 9 false positive or negative results as compared with 3 using the laser Doppler. Four nipples that may otherwise have been converted to free grafts were instead preserved. However, conclusions from this data limit the laser Doppler as a valuable supplement, but not a replacement, for experienced clinical acumen.
引用
收藏
页码:457 / 460
页数:4
相关论文
共 18 条
[1]   ESTABLISHMENT OF NORMAL RANGES OF LASER DOPPLER BLOOD-FLOW IN AUTOLOGOUS TISSUE-TRANSPLANTS [J].
CLINTON, MS ;
SEPKA, RS ;
BRISTOL, D ;
PEDERSON, WC ;
BARWICK, WJ ;
SERAFIN, D ;
KLITZMAN, B .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 87 (02) :299-309
[2]   REDUCTION MAMMAPLASTY BY INFERIOR PEDICLE TECHNIQUE [J].
COURTISS, EH ;
GOLDWYN, RM .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 59 (04) :500-507
[3]   MINIATURE IMPLANTABLE LASER DOPPLER PROBE MONITORING OF FREE TISSUE TRANSFER [J].
FERNANDO, B ;
YOUNG, VL ;
LOGAN, SE .
ANNALS OF PLASTIC SURGERY, 1988, 20 (05) :434-442
[4]  
FISCHER J C, 1985, Microsurgery, V6, P238, DOI 10.1002/micr.1920060410
[5]  
GRDINGER GP, 1988, CLIN PLAST SURG, V15, P641
[6]  
HEDEN G, 1985, MICROSURG, V6, P11
[7]   PREDICTION OF SKIN FLAP NECROSIS - A COMPARATIVE-STUDY BETWEEN LASER DOPPLER FLOWMETRY AND FLUORESCEIN TEST IN A RAT MODEL [J].
HEDEN, P ;
JURELL, G ;
ARNANDER, C .
ANNALS OF PLASTIC SURGERY, 1986, 17 (06) :485-488
[8]   REGIONAL VARIATIONS OF LASER DOPPLER BLOOD-FLOW IN ISCHEMIC SKIN FLAPS [J].
HICKERSON, WL ;
COLGIN, SL ;
PROCTOR, KG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (02) :319-326
[9]   ROUTINE USE OF LASER DOPPLER FLOWMETRY FOR MONITORING AUTOLOGOUS TISSUE-TRANSPLANTS [J].
JENKINS, S ;
SEPKA, R ;
BARWICK, WJ .
ANNALS OF PLASTIC SURGERY, 1988, 21 (05) :423-426
[10]   MONITORS FOR THE CUTANEOUS MICROCIRCULATION [J].
JONES, BM .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 73 (05) :843-850