SELECTIVE CONTINUOUS FLOW-STOPPED FLOW-CONTINUOUS FLOW DETERMINATION OF SULFITE IN WHITE WINES USING IMMOBILIZED SULFITE OXIDASE ON A ROTATING REACTOR

被引:10
|
作者
REZENDE, MO
MOTTOLA, HA
机构
[1] OKLAHOMA STATE UNIV,DEPT CHEM,STILLWATER,OK 74078
[2] UNIV SAO PAULO,DEPT QUIM & FIS MOLEC,BR-13560970 SAO CARLOS,SP,BRAZIL
关键词
SULFITE DETERMINATION; WHITE WINES; CONTINUOUS FLOW-STOPPED FLOW PROCESSING; IMMOBILIZED SULFITE OXIDASE;
D O I
10.1039/an9941902093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sulfite ion in white wines has been selectively determined using the sulfite oxidase [EC 1.8.3.1] catalysis of sulfite oxidation in the presence of hexacyanoferrate(III) as the electron acceptor. The hexacyanoferrate(II) produced was detected amperometrically at a stationary Pt ring electrode (pH = 7.50; applied potential, +0.380 V versus Ag-AgCl: 3.0 mol l(-1) NaCl). Ascorbic acid, the most serious interferent in the determination was eliminated before detection by passing the sample through a column with immobilized ascorbate oxidase [EC 1.10.3.3]. Application of the method of standard additions is also possible without the elimination of ascorbate. An unsegmented continuous flow stream passes the sample/reagent(s) through the column and directs it/them to the cell where contact is made with immobilized sulfite oxidase on a rotating disc. This disc is located at the bottom of the cell, while the Pt electrode is located at the top of the cell. The results of determinations using the proposed method correlate well with those of determinations conducted using the official Association of Analytical Chemists (AOAC) modified Monier-Williams method.
引用
收藏
页码:2093 / 2096
页数:4
相关论文
共 50 条
  • [1] DETERMINATION OF SULFITE IN WHITE WINE BY AMPEROMETRIC FLOW-INJECTION ANALYSIS WITH AN IMMOBILIZED SULFITE OXIDASE REACTOR
    MATSUMOTO, K
    MATSUBARA, H
    UKEDA, H
    OSAJIMA, Y
    AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1989, 53 (09): : 2347 - 2353
  • [2] Continuous flow stopped flow and rotating bioreactors in the determination of glucose
    Lapierre, AV
    Olsina, RA
    Raba, J
    ANALYTICAL CHEMISTRY, 1998, 70 (17) : 3679 - 3684
  • [3] FLOW-INJECTION DETERMINATION OF SULFITE AND ASSAY OF SULFITE OXIDASE
    MASOOM, M
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1986, 179 : 399 - 405
  • [4] Determination of sulfite in beer samples using an amperometric fill and flow channel biosensor employing sulfite oxidase
    Zhao, M
    Hibbert, DB
    Gooding, JJ
    ANALYTICA CHIMICA ACTA, 2006, 556 (01) : 195 - 200
  • [5] Continuous-flow/stopped-flow system for determination of ascorbic acid using an enzymatic rotating bioreactor
    Messina, GA
    Torriero, AAJ
    De Vito, IE
    Raba, J
    TALANTA, 2004, 64 (04) : 1009 - 1017
  • [6] Continuous-flow/stopped-flow system for enzyme immunoassay using a rotating bioreactor: determination of Chagas disease
    Salinas, E
    Torriero, AAJ
    Battaglini, F
    Sanz, MI
    Olsina, R
    Raba, J
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (02): : 313 - 321
  • [7] OXALATE DETERMINATION BY IMMOBILIZED OXALATE OXIDASE IN A CONTINUOUS-FLOW SYSTEM
    BAIS, R
    POTEZNY, N
    EDWARDS, JB
    ROFE, AM
    CONYERS, RAJ
    ANALYTICAL CHEMISTRY, 1980, 52 (03) : 508 - 511
  • [8] CONTINUOUS-FLOW CHEMI-LUMINESCENCE DETERMINATION OF SULFITE AND SULFUR-DIOXIDE
    KOUKLI, II
    SARANTONIS, EG
    CALOKERINOS, AC
    ANALYST, 1988, 113 (04) : 603 - 608
  • [9] AUTOMATIC CONTINUOUS-FLOW DETERMINATION OF SULFITE IN THE PRESENCE OF A HIGH-CONCENTRATION OF THIOSULFATE
    COSANO, JS
    DECASTRO, MDL
    VALCARCEL, M
    ANALYTICA CHIMICA ACTA, 1995, 302 (2-3) : 269 - 274
  • [10] STUDIES WITH A SULFITE OXIDASE-MODIFIED CARBON PASTE ELECTRODE FOR DETECTION DETERMINATION OF SULFITE ION AND SO2(G) IN CONTINUOUS-FLOW SYSTEMS
    NADER, PA
    VIVES, SS
    MOTTOLA, HA
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 284 (02): : 323 - 333