BIOELECTRIC IMPEDANCE DETECTS FLUID RETENTION IN PATIENTS UNDERGOING CARDIOPULMONARY BYPASS

被引:27
作者
GONZALEZ, J
MORRISSEY, T
BYRNE, T
RIZZO, R
WILMORE, D
机构
[1] BRIGHAM & WOMENS HOSP,BOSTON,MA 02115
[2] HARVARD UNIV,SCH MED,SURG METAB & NUTR LABS,BOSTON,MA
[3] HARVARD UNIV,SCH MED,DEPT SURG,DIV CARDIAC SURG,BOSTON,MA 02115
关键词
D O I
10.1016/S0022-5223(05)80016-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Excessive fluid accumulation is associated with increased morbidity and prolonged convalescence after cardiopulmonary bypass. However, water fluctuations are difficult to assess solely on the basis of changes in body weight and fluid balance. Bioelectric impedance analysis is a simple, rapid, noninvasive bedside technique that measures the resistance of the body to a weak alternating current (50 kHz). The change in resistance is inversely proportional to the change in total body water, To investigate the relationship between body weight, fluid balance, and resistance, 18 patients who had cardiopulmonary bypass (9 men, 9 women, aged 61 +/- 3 years, weighing 80 +/- 4 kg, with ejection fraction 54% +/- 3% and bypass time 113 +/- 8 minutes [mean plus or minus standard error of the mean]) were followed up for 7 postoperative days. Body weight, fluid balance, and whole body and regional resistance were determined at 24-hour intervals. In the immediate postoperative period, fluid retention was accurately detected by simultaneous measurements of weight gain and decreased resistance (p < 0.001). Both measurements detected the initiation of diuresis by postoperative day 2 (p < 0.01). Whole body resistance returned to baseline values by day 7 (p > 0.05), and body weight returned to baseline on day 4 (p > 0.05), Change in weight and change in whole body resistance were highly correlated with cumulative fluid balance (r = 0.84, p < 0.001, and r = -0.81,p < 0.001, respectively), and these two measures were also related to each other throughout the study (r = -0.89, p < 0.001). The initial change in resistance was the best measurement associated with postoperative outcome (p less than or equal to 0.01). The data suggest that the measurement of electric resistance across the body can accurately detect acute changes in total body water and in fluid redistribution through the body. However, determining the relative day-to-day change in whole body resistance seems more appropriate than calculating absolute fluid changes over time. Bioelectric impedance offers a simple, rapid, noninvasive method to monitor serial changes in total body water, This technique can be useful in situations in which rapid alterations in water compartments occur, and it may be useful in predicting outcome after cardiopulmonary bypass.
引用
收藏
页码:111 / 118
页数:8
相关论文
共 23 条
[11]   ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
KUSHNER, RF ;
SCHOELLER, DA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (03) :417-424
[12]   IS THE IMPEDANCE INDEX (HT2/R) SIGNIFICANT IN PREDICTING TOTAL-BODY WATER [J].
KUSHNER, RF ;
SCHOELLER, DA ;
FJELD, CR ;
DANFORD, L .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 56 (05) :835-839
[13]   POSTOPERATIVE FLUID OVERLOAD - NOT A BENIGN PROBLEM [J].
LOWELL, JA ;
SCHIFFERDECKER, C ;
DRISCOLL, DF ;
BENOTTI, PN ;
BISTRIAN, BR .
CRITICAL CARE MEDICINE, 1990, 18 (07) :728-733
[14]   VALIDATION OF TETRAPOLAR BIOELECTRICAL IMPEDANCE METHOD TO ASSESS HUMAN-BODY COMPOSITION [J].
LUKASKI, HC ;
BOLONCHUK, WW ;
HALL, CB ;
SIDERS, WA .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (04) :1327-1332
[15]  
MOORE FD, 1963, BODY CELL MASS ITS S
[16]  
PACIFICO A, 1970, CIRCULATION, V61, P331
[17]   ALTERATIONS IN BODY-FLUID CONTENT CAN BE DETECTED BY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
SCHELTINGA, MR ;
JACOBS, DO ;
KIMBROUGH, TD ;
WILMORE, DW .
JOURNAL OF SURGICAL RESEARCH, 1991, 50 (05) :461-468
[18]   IMPEDANCE ELECTRODES POSITIONED ON PROXIMAL PORTIONS OF LIMBS QUANTIFY FLUID COMPARTMENTS IN DOGS [J].
SCHELTINGA, MR ;
HELTON, WS ;
ROUNDS, J ;
JACOBS, DO ;
WILMORE, DW .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (05) :2039-2044
[19]   IDENTIFYING BODY-FLUID DISTRIBUTION BY MEASURING ELECTRICAL-IMPEDANCE [J].
SCHELTINGA, MR ;
JACOBS, DO ;
KIMBROUGH, TD ;
WILMORE, DW .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1992, 33 (05) :665-670
[20]  
THOMASSET A, 1963, LYON MED, V208, P107