REAL EAR ATTENUATION AT THRESHOLD FOR 3 AUDIOMETRIC HEADPHONE DEVICES - IMPLICATIONS FOR MAXIMUM PERMISSIBLE AMBIENT NOISE-LEVEL STANDARDS

被引:16
作者
FRANKS, JR
ENGEL, DP
THEMANN, CL
机构
[1] Department of health and human services, Public health services, Centers for Disease Control, National lnstitute for Occupational Safety and Health, Division of Biomedical and Behavioral Science, Physical Agents Effects Branch, Cincinnati, OH
关键词
D O I
10.1097/00003446-199202000-00004
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Attenation measurements were made using the ANSI S12.6-1984 protocol on a standard Telephonics headset with TDH-50P earphones and Model 51 cushions, Amplivox Audiocups headphone enclosures, and Peltor AudioMate headphone enclosures. Each of the enclosures housed Telephonics TDH-50P earphones with Model 51 cushions. The mean attenuation values obtained were compared with those previously reported, and reasons for discrepancies were analyzed. Pure-tone threshold shifts in background noise complying with ANSI S3.1-1977 and Occupational Safety and Health Administration (1983) maximum permissible ambient noise level standards were estimated on the basis of the attenuation values for each headphone device, and the adequacy of these current standards for accurate pure-tone threshold assessment was considered. The results indicated that Model 51 cushions alone are insufficient to attenuate the ambient noise levels permitted under ANSI S3.1-1977, and even the utilizaion of noise-eexcluding headphone enclosures does not reduce the background noise levels permitted under the Occupational Safety and Health Administration (1983) to a sufficient degree to permitt testing down to 0 dB HL.
引用
收藏
页码:2 / 10
页数:9
相关论文
共 22 条
[1]   SOUND-ATTENUATION OF TDH-39 EARPHONES IN A DIFFUSE FIELD OF NARROW-BAND NOISE [J].
ARLINGER, SD .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1986, 79 (01) :189-191
[2]   LIMITATIONS ON USE OF CIRCUMAURAL EARPHONES [J].
BENSON, RW ;
CHARAN, KK ;
DAY, JW ;
HARRIS, JD ;
NIEMOELLER, AF ;
RUDMOSE, W ;
SHAW, EAG ;
WEISSLER, PG .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1967, 41 (03) :713-+
[3]   INFLUENCE OF PHYSIOLOGICAL NOISE AND THE OCCLUSION EFFECT ON THE MEASUREMENT OF REAL-EAR ATTENUATION AT THRESHOLD [J].
BERGER, EH ;
KERIVAN, JE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1983, 74 (01) :81-94
[4]   COMPARISON OF THE NOISE ATTENUATION OF 3 AUDIOMETRIC EARPHONES, WITH ADDITIONAL DATA ON MASKING NEAR THRESHOLD [J].
BERGER, EH ;
KILLION, MC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1989, 86 (04) :1392-1403
[5]   REAL-EAR ATTENUATION CHARACTERISTICS OF SELECTED NOISE-EXCLUDING AUDIOMETRIC RECEIVER ENCLOSURES [J].
COPELAND, AB ;
MOWRY, HJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1971, 49 (06) :1757-&
[6]   ATTENUATION PROVIDED BY 4 DIFFERENT AUDIOMETRIC EARPHONE SYSTEMS [J].
FRANK, T ;
WRIGHT, DC .
EAR AND HEARING, 1990, 11 (01) :70-78
[7]  
FRANKS JR, 1989, HEAR INSTRUM, V40, P29
[8]   NOISE ATTENUATION CHARACTERISTICS FOR SUPRA-AURAL AUDIOMETRIC HEADSETS USING THE MODELS MX-41-AR AND 51 EARPHONE CUSHIONS [J].
MICHAEL, PL ;
BIENVENUE, GR .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 70 (05) :1235-1238
[9]   COMPARISON OF ACOUSTICAL PERFORMANCE BETWEEN A NEW ONE-PIECE EARPHONE CUSHION AND THE CONVENTIONAL 2-PIECE MX-41-AR CUSHION [J].
MICHAEL, PL ;
BIENVENUE, GR .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 67 (02) :693-701
[10]   CALIBRATION DATA FOR A CIRCUMAURAL HEADSET DESIGNED FOR HEARING TESTING [J].
MICHAEL, PL ;
BIENVENUE, GR .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 60 (04) :944-950