OPTICAL MEASUREMENT OF THE AXIAL EYE LENGTH BY LASER DOPPLER INTERFEROMETRY

被引:0
|
作者
HITZENBERGER, CK
机构
关键词
BIOMETRY; OCULOMETRY; EYE LENGTH MEASUREMENT; LASER INTERFEROMETRY; LASER DOPPLER INTERFEROMETRY;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A new technique has been developed to determine the axial length of the human eye in vivo. Based on laser interferometry in conjunction with the Doppler technique, it uses partially coherent light. This new technique complies with laser safety regulations. High accuracy is achieved, the optical length (OL) can be determined within +/- 30-mu-m, and the reproducibility of the geometric eye length is greater than +/- 25-mu-m. Possible errors are discussed. First comparisons with the ultrasound technique yield good agreement for emmetropic subjects and for subjects with a myopia of up to 10 diopters. The advantages of the laser doppler interferometry (LDI) technique are high accuracy, high transversal resolution, and more comfort for the patient (it is a noncontact method; no anesthesia is needed). Possible future applications of LDI, like measurements of fundus profiles and of retinal thickness, are mentioned.
引用
收藏
页码:616 / 624
页数:9
相关论文
共 50 条
  • [21] ULTRASOUND VELOCITIES FOR AXIAL EYE LENGTH MEASUREMENT
    HOFFER, KJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (05): : 554 - 562
  • [22] THE ACCURACY OF ULTRASONIC MEASUREMENT OF THE AXIAL LENGTH OF THE EYE
    BINKHORST, RD
    OPHTHALMIC SURGERY AND LASERS, 1981, 12 (05): : 363 - 365
  • [23] Evaluation of Axial Length Measurement of the Eye Using Partial Coherence Interferometry and Ultrasound in Cases of Macular Disease
    Kojima, Takashi
    Tamaoki, Akeno
    Yoshida, Norihiko
    Kaga, Tatsushi
    Suto, Chikako
    Ichikawa, Kazuo
    OPHTHALMOLOGY, 2010, 117 (09) : 1750 - 1754
  • [24] High sensitive measurement of the human axial eye length in vivo with Fourier domain low coherence interferometry
    Grajciar, Branislav
    Pircher, Michael
    Hitzenberger, Christoph K.
    Findl, Oliver
    Fercher, Adolf F.
    OPTICS EXPRESS, 2008, 16 (04) : 2405 - 2414
  • [25] In vivo length measurement of the eye with selective coherence interferometry
    Bende, M
    Bende, T
    Berret, R
    Oltrup, T
    Jean, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U1256 - U1256
  • [26] Validation of laser Doppler interferometric measurements in vivo of axial eye length and thickness of fundus layers in chicks
    Schmid, GE
    Papastergiou, GI
    Nickla, DL
    Riva, CE
    Lin, T
    Stone, RA
    Laties, AM
    CURRENT EYE RESEARCH, 1996, 15 (06) : 691 - 696
  • [27] Axial length scanning: Laser interferometry versus ultrasound biometry
    Badoza, D
    Iglesias, A
    Ganly, M
    Geria, M
    Marengo, J
    Zunino, MJ
    Argento, C
    ANNALS OF OPHTHALMOLOGY, 2004, 36 (01) : 17 - 20
  • [28] Large coherence length swept source for axial length measurement of the eye
    Chong, Changho
    Suzuki, Takuya
    Totsuka, Kohki
    Morosawa, Atsushi
    Sakai, Tooru
    APPLIED OPTICS, 2009, 48 (10) : D144 - D150
  • [29] Measurement of changes in optical path length and reflectivity with phase-shifting laser feedback interferometry
    Ovryn, B
    Andrews, JH
    APPLIED OPTICS, 1999, 38 (10) : 1959 - 1967
  • [30] AXIAL LENGTH OF EYE
    ITIN, W
    BRAWANT, L
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1968, 65 (06) : 933 - &