Advantages of mini-multileaf in stereotactic radiotherapy

被引:2
作者
Kurup, P. G. G. [1 ]
Murali, V. [1 ]
Sankar, A. [1 ]
机构
[1] Apollo Specialty Hosp, Dept Radiotherapy, 320,Mt Rd, Chennai 600035, Tamil Nadu, India
关键词
Dose-volume histograms; mini-multileaf collimator; stereotactic radiosurgery;
D O I
10.4103/0971-6203.31144
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Over the past few decades, cones of different diameter (12.5 mm to 40 mm) were used for treatment of intracranial lesions. These give very focused dose delivery to the target with minimum dose to outside normal brain tissues. This study is intended to compare the older method of arc-based stereotactic treatments using cones with the new mini-multileaf collimator (mMLC). Treatment plans are made for various sites of intracranial lesions with the cones and mMLC. In case of nonspherical lesions, more than one isocenter is used to get an optimum dose distribution with cones, while a single isocenter is sufficient with mMLC. Treatment plans are compared for irregular lesions using cones with multiple isocenters and mMLC. It is observed that conformity index and dose heterogeneity are better for mMLC based treatments.
引用
收藏
页码:12 / 17
页数:6
相关论文
共 7 条
[1]   A comparison of arc-based and static mini-multileaf collimator-based radiosurgery treatment plans [J].
Kubo, HD ;
Pappas, CTE ;
Wilder, RB .
RADIOTHERAPY AND ONCOLOGY, 1997, 45 (01) :89-93
[2]  
Loeffler J S, 1990, Oncology (Williston Park), V4, P21
[3]   VARIABLES ASSOCIATED WITH THE DEVELOPMENT OF COMPLICATIONS FROM RADIOSURGERY OF INTRACRANIAL TUMORS [J].
NEDZI, LA ;
KOOY, H ;
ALEXANDER, E ;
GELMAN, RS ;
LOEFFLER, JS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :591-599
[4]   IMPLEMENTATION OF MULTIPLE ISOCENTER TREATMENT FOR DYNAMIC RADIOSURGERY [J].
RAMANI, R ;
OBRIEN, PF ;
DAVEY, P ;
SCHWARTZ, ML ;
YOUNG, CS ;
LIGHTSTONE, AW ;
MASON, DLD .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (811) :731-735
[5]   Comparison of miniature multileaf collimation (MMLC) with circular collimation for stereotactic treatment [J].
Shiu, AS ;
Kooy, HM ;
Ewton, JR ;
Tung, SS ;
Wong, J ;
Antes, K ;
Maor, MH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (03) :679-688
[6]   Miniature multileaf collimator as an alternative to traditional circular collimators for stereotactic radiosurgery and stereotactic radiotherapy [J].
Urie, MM ;
Lo, YC ;
Litofsky, S ;
FitzGerald, TJ .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2001, 76 (01) :47-62
[7]   Considerations on treatment efficiency of different conformal radiation therapy techniques for prostate cancer [J].
Verellen, D ;
Linthout, N ;
Soete, G ;
Van Acker, S ;
De Roover, P ;
Storme, G .
RADIOTHERAPY AND ONCOLOGY, 2002, 63 (01) :27-36