摘要
To investigate the effect of a sustained fall in intrathoracic pressure (Mueller manoeuvre) on blood flow through the right heart and on systemic venous dynamics, 16 patients were studied using thermodilution, cinevenograms and simultaneous pressure recordings with two micromanometric transducers. The reductions in airway pressure (median [range]) during two graded Mueller manoeuvres were 25 (20-30) and 42 (22-52) mmHg. Right atrial mean pressure decreased by 17 (2-25) mmHg during the former and 38 (0-49) mmHg during the latter, and simultaneously, pressure gradients of 23 (1-32) and 45 (1-82) mmHg developed between the inferior vena cava and right atrium (P<0.003 for all). Internal jugular venous pressure decreased by 16 (4-25) and 24 (4-43) mmHg (P<0.03 for both), respectively, and no pressure gradient developed between internal jugular and superior caval veins. The minimum diameter of the proximal inferior vena cava decreased by 69 (-49-84)% (P=0.002) during the greater manoeuvre. Cardiac index tended to increase by 26 (-17-40)% (P<0.066) during the lesser manoeuvre but did not change statistically significantly during the greater. In conclusion, during negative intrathoracic pressure caused acutely by the Mueller manoeuvre, right atrial pressure decreases and the inferior vena cava collapses partially at or below the diaphragm. Despite a significant venous obstruction between the lower body and right atrium, blood flow through the right heart increases or remains constant.
引用
收藏
页码:1293 / 1299
页数:7
相关论文
共 32 条
  • [1] DOPPLER ECHOCARDIOGRAPHIC ANALYSIS OF CARDIAC FLOW DURING THE MUELLER MANEUVER
    ANDREAS, S
    WERNER, GS
    SOLD, G
    WIEGAND, V
    KREUZER, H
    [J]. EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1991, 21 (01) : 72 - 76
  • [2] CARDIAC-TAMPONADE AND PERICARDIAL-EFFUSION - RESPIRATORY VARIATION IN TRANSVALVULAR FLOW VELOCITIES STUDIED BY DOPPLER ECHOCARDIOGRAPHY
    APPLETON, CP
    HATLE, LK
    POPP, RL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (05) : 1020 - 1030
  • [3] SUPERIOR VENA-CAVA AND HEPATIC VEIN DOPPLER ECHOCARDIOGRAPHY IN HEALTHY-ADULTS
    APPLETON, CP
    HATLE, LK
    POPP, RL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (05) : 1032 - 1039
  • [4] LEFTWARD SEPTAL DISPLACEMENT DURING RIGHT VENTRICULAR LOADING IN MAN
    BRINKER, JA
    WEISS, JL
    LAPPE, DL
    RABSON, JL
    SUMMER, WR
    PERMUTT, S
    WEISFELDT, ML
    [J]. CIRCULATION, 1980, 61 (03) : 626 - 633
  • [5] LUNG-VOLUME DEPENDENCE OF ESOPHAGEAL PRESSURE IN THE NECK
    BROWN, IG
    MCCLEAN, PA
    WEBSTER, PM
    HOFFSTEIN, V
    ZAMEL, N
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (06) : 1849 - 1854
  • [6] CHANGES IN TRACHEAL CROSS-SECTIONAL AREA DURING MUELLER AND VALSALVA MANEUVERS IN HUMANS
    BROWN, IG
    WEBSTER, PM
    ZAMEL, N
    HOFFSTEIN, V
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (06) : 1865 - 1870
  • [7] EFFECT OF INTRA-THORACIC PRESSURE ON LEFT-VENTRICULAR PERFORMANCE
    BUDA, AJ
    PINSKY, MR
    INGELS, NB
    DAUGHTERS, GT
    STINSON, EB
    ALDERMAN, EL
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (09) : 453 - 459
  • [8] CARDIAC-TAMPONADE - CHARACTERISTIC DOPPLER OBSERVATIONS
    BURSTOW, DJ
    OH, JK
    BAILEY, KR
    SEWARD, JB
    TAJIK, AJ
    [J]. MAYO CLINIC PROCEEDINGS, 1989, 64 (03) : 312 - 324
  • [9] HEMODYNAMICS OF THE MUELLER MANEUVER IN MAN - RIGHT AND LEFT HEART MICROMANOMETRY AND DOPPLER ECHOCARDIOGRAPHY
    CONDOS, WR
    LATHAM, RD
    HOADLEY, SD
    PASIPOULARIDES, A
    [J]. CIRCULATION, 1987, 76 (05) : 1020 - 1028
  • [10] THERMODILUTION METHOD FOR MEASURING CARDIAC-OUTPUT
    CONWAY, J
    LUNDJOHANSEN, P
    [J]. EUROPEAN HEART JOURNAL, 1990, 11 : 17 - 20