DETERMINATION OF COBALT IN BLOOD USING CATHODIC STRIPPING VOLTAMMETRY

被引:26
作者
GODLEWSKA, B
GOLIMOWSKI, J
HULANICKI, A
VAN DEN BERG, CMG
机构
[1] UNIV LIVERPOOL, DEPT EARTH SCI, OCEANOG LAB, LIVERPOOL L69 3BX, MERSEYSIDE, ENGLAND
[2] UNIV WARSAW, INST CHEM, PL-15443 BIALYSTOK, POLAND
[3] UNIV WARSAW, DEPT CHEM, PL-02093 WARSAW, POLAND
关键词
COBALT; CATHODIC STRIPPING VOLTAMMETRY; BLOOD;
D O I
10.1039/an9952000143
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to determine low levels of cobalt in whole blood, serum and plasma, Samples of blood (0.2 mi) were mineralized at 160 degrees C in the presence of concentrated nitric acid, Residual organic matter was destroyed by digestion using ultraviolet irradiation after dilution with water, The cobalt concentration was determined by catalytic cathodic stripping voltammetry (CSV) preceded by adsorptive collection of cobalt complexed with diphenylglyoxime (DPG). The optimized analytical conditions for the CSV analysis included a DPG concentration of 0.5 mu mol l(-1), 0.05 mol l(-1) ammonium chloride buffer (pH 9.3), 0.15 mol l(-1) nitrite, a deposition potential of -0.75 V, an adsorption time of 30-120 s and a negative potential scan using the differential-pulse modulation, The limit of detection was 40 pg of cobalt in 0.2 ml of blood, which was limited by the blank level of cobalt in the reagents after purification.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 50 条
  • [11] DETERMINATION OF TRACES OF MANGANESE BY CATHODIC STRIPPING VOLTAMMETRY
    TANAKA, T
    MURAMATSU, T
    TAKADA, N
    MIZUIKE, A
    BUNSEKI KAGAKU, 1993, 42 (10) : 587 - 591
  • [12] DIRECT DETERMINATION OF COBALT IN UNPURGED OCEANIC SEAWATER BY HIGH-SPEED ADSORPTIVE CATHODIC STRIPPING VOLTAMMETRY
    HERRERAMELIAN, JA
    HERNANDEZBRITO, J
    GELADOCABALLERO, MD
    PEREZPENA, J
    ANALYTICA CHIMICA ACTA, 1994, 299 (01) : 59 - 67
  • [13] Rapid and sensitive determination of cobalt by adsorptive cathodic stripping voltammetry using tin-bismuth alloy electrode
    Zhang, Li
    Pan, Da-wei
    Liu, Yang-sheng
    IONICS, 2016, 22 (05) : 721 - 729
  • [14] Determination of trace lead in copper by cathodic stripping voltammetry
    Ishiyama, T
    Abe, K
    Tanaka, T
    Mizuike, A
    ANALYTICAL SCIENCES, 1996, 12 (02) : 263 - 265
  • [15] Determination of pyrithione in natural waters by cathodic stripping voltammetry
    Mackie, DS
    van den Berg, CMG
    Readman, JW
    ANALYTICA CHIMICA ACTA, 2004, 511 (01) : 47 - 53
  • [16] Simultaneous determination of trace amounts of nickel, cobalt, and zinc in the wastewater of a galvanic workshop by using adsorptive cathodic stripping voltammetry
    B. Rezaei
    E. Rezaei
    Journal of Analytical Chemistry, 2006, 61 : 262 - 265
  • [17] SQUARE WAVE CATHODIC STRIPPING VOLTAMMETRY ADSORPTIVE FOR NICKEL AND COBALT ANALYSIS
    Saryati
    Rukihati
    Sumardjo
    INDONESIAN JOURNAL OF CHEMISTRY, 2006, 6 (02) : 161 - 164
  • [18] Determination of nickel and cobalt in refined beet sugar by adsorptive cathodic stripping voltammetry without sample pretreatment
    Sancho, D
    Debán, L
    Campos, I
    Pardo, R
    Vega, M
    FOOD CHEMISTRY, 2000, 71 (01) : 139 - 145
  • [19] COBALT IN DUTCH MILK POWDER - DETERMINATION BY DIFFERENTIAL-PULSE ADSORPTIVE CATHODIC-STRIPPING VOLTAMMETRY
    KOOPS, J
    KLOMP, H
    NETHERLANDS MILK AND DAIRY JOURNAL, 1991, 45 (02): : 127 - 138
  • [20] Simple and rapid determination of trace iodide by cathodic stripping voltammetry
    Yang, Lingxi
    Zou, Lina
    Li, Gaiping
    Ye, Baoxian
    TALANTA, 2016, 147 : 634 - 640