REVISION THR AFTER PERIPROSTHETIC FEMORAL FRACTURES - AN ANALYSIS OF 23 CASES

被引:43
作者
KOLSTAD, K
机构
[1] Department of Orthopedics, Uppsala University, University Hospital, S-751 85, Uppsala
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1994年 / 65卷 / 05期
关键词
D O I
10.3109/17453679409000900
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
23 consecutive proximal femoral fractures in 22 patients, who had previously undergone total hip arthroplasty, were treated with long revision stems. At the time of the fracture, 21 stems were loose. An uncemented Wagner revision stem was used in 9 cases and different conventional revision stems in the others. All fractures healed, but 7 of the conventional revision implants rapidly loosened again, whereas so far none of the Wagner stems have loosened.
引用
收藏
页码:505 / 508
页数:4
相关论文
共 17 条
[11]  
MJOBERG B, 1984, ACTA ORTHOP SCAND, V55, P504
[12]  
OLERUD S, 1984, CLIN ORTHOP RELAT R, V191, P64
[13]   FEMORAL STEM FIXATION IN HIP-REPLACEMENT - A BIOMECHANICAL COMPARISON OF CEMENTLESS AND CEMENTED PROSTHESES [J].
PHILLIPS, TW ;
MESSIEH, SS ;
MCDONALD, PD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (03) :431-434
[14]  
RAHN BA, 1987, OTOLARYNG CLIN N AM, V20, P425
[15]  
Serocki J H, 1992, J Arthroplasty, V7, P129, DOI 10.1016/0883-5403(92)90005-B
[16]  
WAGNER H, 1989, ORTHOPADE, V18, P438
[17]  
WAGNER H, 1991, NONCEMENTED TOTAL HI, P301