Dynamic assessment of carotid plaque motion

被引:7
作者
Akkus, Zeynettin [1 ,2 ]
Ramnarine, Kumar V. [1 ]
机构
[1] Univ Hosp Leicester, NHS Trust, Dept Med Phys, Leicester, Leics, England
[2] KTH Royal Inst Technol, Stockholm, Sweden
关键词
Diagnostic imaging; vessel wall motion; signal processing; engineering; physics; vascular;
D O I
10.1258/ult.2010.010019
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Assessment of dynamic plaque behaviour may help identify vulnerable carotid plaque before rupture and hence has potential clinical value for screening patients at risk of stroke. The aim of this study was to develop non-invasive ultrasound methods for quantifying dynamic plaque and vessel wall behaviour and assess their potential clinical utility. Ultrasound data from the carotid arteries of one normal subject and four patients with atherosclerotic disease were acquired using a 10 MHz linear array transducer recording raw RF/IQ data at a frame rate up to 80 Hz for 3-6 seconds. Image reconstruction and processing was performed using Matlab. Speckle tracking techniques were developed to characterize: (1) intraplaque deformation; and (2) plaque surface and vessel wall motion. Speckle tracking techniques were able to measure the range of intraplaque tissue deformation (-1.3 to 1.7 mm), plaque surface displacement (0.2-0.7 mm) and vessel wall radial strain (0.02-0.13) throughout the cardiac cycle. The feasibility of using an intraplaque deformation parameter, based on the deformation of a square template, is demonstrated. Speckle tracking techniques can be used to assess dynamic carotid plaque behaviour. Further work is required to evaluate how best to quantify biomechanical behaviour to help predict plaque rupture and hence improve risk stratification models for stroke.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 23 条
[1]   Carotid intraplaque hemorrhage detected by magnetic resonance imaging predicts embolization during carotid endarterectomy [J].
Altaf, Nishath ;
Beech, Andrew ;
Goode, Stephen D. ;
Gladman, John R. ;
Moody, Alan R. ;
Auer, Dorothee P. ;
MacSweeney, Shane T. .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (01) :31-36
[2]   Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging [J].
Amundsen, BH ;
Helle-Valle, T ;
Edvardsen, T ;
Torp, H ;
Crosby, J ;
Lyseggen, E ;
Stoylen, A ;
Ihlen, H ;
Lima, JAC ;
Smiseth, OA ;
Slordahl, SA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) :789-793
[3]   Assessment of vulnerable plaque composition by matching the deformation of a parametric plaque model to measured plaque deformation [J].
Baldewsing, RA ;
Schaar, JA ;
Mastik, F ;
Oomens, CWJ ;
van der Steen, AFW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :514-528
[4]   Carotid endarterectomy [J].
Barnett, HJM .
LANCET, 2004, 363 (9420) :1486-1487
[5]   A fluid-structure interaction finite element analysis of pulsatile blood flow through a compliant stenotic artery [J].
Bathe, M ;
Kamm, RD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04) :361-369
[6]   THE LAUSANNE STROKE REGISTRY - ANALYSIS OF 1,000 CONSECUTIVE PATIENTS WITH 1ST STROKE [J].
BOGOUSSLAVSKY, J ;
VANMELLE, G ;
REGLI, F .
STROKE, 1988, 19 (09) :1083-1092
[7]   2 APPROACHES TO MOTION ANALYSIS OF THE ULTRASOUND IMAGE SEQUENCE OF CAROTID ATHEROMATOUS PLAQUE [J].
CHAN, KL .
ULTRASONICS, 1993, 31 (02) :117-123
[8]   Parameters describing motion in carotid artery plaques from ultrasound examination: A reproducibility study [J].
Dahl, T ;
Bang, J ;
Ushakova, A ;
Lydersen, S ;
Myhre, HO .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (09) :1133-1143
[9]   Characterization of plaque components and vulnerability with intravascular ultrasound elastography [J].
de Korte, CL ;
van der Steen, AFW ;
Céspedes, EI ;
Pasterkamp, G ;
Carlier, SG ;
Mastik, F ;
Schoneveld, AH ;
Serruys, PW ;
Bom, N .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1465-1475
[10]  
Evans DH, 2000, PHYSIOL MEAS, V21, P425