SIMULTANEOUS ESTIMATION OF GLOMERULAR-FILTRATION RATE AND RENAL PLASMA-FLOW

被引:0
作者
FRESCO, GF [1 ]
DIGIORGIO, F [1 ]
CURTI, GL [1 ]
机构
[1] IST,CTR EXPTL BIOSTAT & DATA PROC,GENOA,ITALY
关键词
GLOMERULAR FILTRATION RATE; TUBULAR EXCRETION RATE; EFFECTIVE RENAL PLASMA FLOW; CHROMIUM-51-EDTA; TECHNETIUM-99M-MAG3;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Comparing the measurements of both glomerular filtration (GFR) and tubular excretion rates [TER(MAG3)] by multi-sample and single-sample methods has been performed after a single bolus injection of 3.7 MBq Cr-51-EDTA plus 37 MBq (TC)-T-99m-MAG3. Methods: We studied 17 healthy volunteers and 28 patients with a wide range of renal function. For each plasma clearence curve, nine plasma samples were drawn at intervals from 10 to 240 min after injection of tracers. When comparing individual values for GFR and TER (MAG3) from the tracer dilution spaces (VD) with those derived from the analysis of the entire plasma disappearance curves of two radiopharmaceuticals, a good linear correlation appears (r = 0.96). Results: We found that the nadir-error (S-y,S-x) for predicted GFR occurs at 180 min (11.0 ml/min/1.73 m(2)), while the nadir-error for predicted TER (MAG3) is reached at 90 min (26.4 ml/min/1.73 m(2)). Conclusion: In the computation of GFR and TER (MAG3) with a single-sample method, it appears that the mean residence time (t) for each tracer represents the optimum plasma sampling time. Our results suggest that the single injection of Cr-51-EDTA and Tc-99m-MAG3 followed by blood sampling twice permits accurate simultaneous estimation of GFR and TER (MAG3) and, after correction of the latter kinetic parameter, effective renal plasma flow.
引用
收藏
页码:1701 / 1706
页数:6
相关论文
共 24 条
[1]  
Brochner-Mortensen, 1972, SCAND J CLIN LAB INV, V30, P271
[2]  
BROCHNERMORTENS.J, 1969, SCAND J CLIN LAB INV, V23, P301
[3]  
BUBECK B, 1990, J NUCL MED, V31, P1285
[4]   RENAL CLEARANCE DETERMINATION WITH ONE BLOOD-SAMPLE - IMPROVED ACCURACY AND UNIVERSAL APPLICABILITY BY A NEW CALCULATION PRINCIPLE [J].
BUBECK, B .
SEMINARS IN NUCLEAR MEDICINE, 1993, 23 (01) :73-86
[5]  
CONSTABLE AR, 1980, RADIONUCLIDES NEPHRO, P62
[6]   GLOMERULAR-FILTRATION RATE ESTIMATION BASED ON A SINGLE BLOOD SAMPLE [J].
FISHER, M ;
VEALL, N .
BRITISH MEDICAL JOURNAL, 1975, 2 (5970) :542-542
[7]  
FRITZBERG AR, 1986, J NUCL MED, V27, P111
[8]  
GARNETT ES, 1967, LANCET, V2, P818
[9]  
GORDON I, 1991, J NUCL MED, V32, P1704
[10]  
HOR G, 1968, RADIOISOTOPE KREISLA, V8, P327