COMBINATION OF ANTITACHYCARDIA PACEMAKER AND AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR FOR VENTRICULAR-TACHYCARDIA

被引:31
作者
MANZ, M
GERCKENS, U
FUNKE, HD
KIRCHHOFF, PG
LUDERITZ, B
机构
[1] UNIV BONN,DEPT CARDIOL,D-5300 BONN 1,FED REP GER
[2] UNIV BONN,DEPT CARDIOVASC SURG,D-5300 BONN 1,FED REP GER
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1986年 / 9卷 / 05期
关键词
D O I
10.1111/j.1540-8159.1986.tb05415.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:676 / 684
页数:9
相关论文
共 50 条
[31]   Initiation of Ventricular Tachycardia by Interruption of Pacemaker-Mediated Tachycardia in a Patient with a Dual-Chamber Implantable Cardioverter Defibrillator [J].
Van Gelder, Berry M. ;
Meijer, Albert ;
Dekker, Lukas R. ;
Bracke, Frank A. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (09) :1227-1230
[32]   TERMINATION OF VENTRICULAR-TACHYCARDIA BY AN IMPLANTABLE ATRIAL PACEMAKER AND EXTERNAL PACEMAKER ACTIVATOR [J].
TANABE, A ;
IKEDA, H ;
FUJIYAMA, M ;
FURUTA, YI ;
MATSUMURA, J ;
OHBAYASHI, J ;
UTSU, F ;
TOSHIMA, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (04) :532-537
[33]   Failure of an Implantable Cardioverter Defibrillator to Terminate Ventricular Tachycardia: Why? [J].
Conti, Letizia ;
Tran, Nam ;
Burri, Haran ;
Zimmermann, Marc .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (02) :228-230
[34]   CLINICAL NONSUSTAINED VENTRICULAR-TACHYCARDIA - IS IMPLANTATION OF THE CARDIOVERTER DEFIBRILLATOR JUSTIFIABLE [J].
DESHPANDE, S ;
ANDERSON, A ;
DHALA, A ;
JAZAYERI, M ;
SRA, J ;
AXTELL, K ;
AKHTAR, M .
CIRCULATION, 1992, 86 (04) :394-394
[35]   Pacemaker/implantable cardioverter-defibrillator problem: Right ventricular lead missensing in a biventricular implantable cardioverter-defibrillator [J].
Otten, Richard F. ;
Foreman, Lynne D. ;
Groh, William J. .
HEART RHYTHM, 2008, 5 (01) :158-159
[36]   Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter-defibrillator recipients [J].
Yanagisawa, Satoshi ;
Inden, Yasuya ;
Sato, Yuki ;
Watanabe, Ryo ;
Goto, Takayuki ;
Kondo, Shun ;
Tachi, Masaya ;
Iwawaki, Tomoya ;
Yamauchi, Ryota ;
Hiramatsu, Kei ;
Shimojo, Masafumi ;
Tsuji, Yukiomi ;
Shibata, Rei ;
Murohara, Toyoaki .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (04) :821-831
[37]   Does Volume Overload Predict Failed Antitachycardia Pacing Therapy for Ventricular Tachycardia in Patients With an Implantable Cardioverter-Defibrillator? [J].
Hosseini-khalili, Alireza ;
Kluger, Jeffrey .
CIRCULATION, 2014, 130
[38]   Efficacy and safety of different antitachycardia pacing sites in the termination of ventricular tachycardia in patients with biventricular implantable cardioverter-defibrillator [J].
Haghjoo, Majid ;
Hajahmadi, Mozhgan ;
Fazelifar, Amir Farjam ;
Sadr-Ameli, Mohammad Ali .
EUROPACE, 2011, 13 (04) :509-513
[39]   THE TREATMENT OF VENTRICULAR-TACHYCARDIA USING AN AUTOMATIC TACHYCARDIA TERMINATING PACEMAKER [J].
GRIFFIN, JC ;
MASON, JW ;
ROSS, DL ;
CALFEE, RV .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (05) :582-588
[40]   TREATMENT OF VENTRICULAR-TACHYCARDIA AND FIBRILLATION WITH LOW-ENERGY CARDIOVERSION BY THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR (ICD) [J].
SIEBELS, J ;
SCHNEIDER, MAE ;
KUCK, KH .
ZEITSCHRIFT FUR KARDIOLOGIE, 1993, 82 (11) :683-691