FLOW-INJECTION ANALYSIS FOR THE MEASUREMENT OF PENICILLIN-V IN FERMENTATION MEDIA

被引:17
作者
CARLSEN, M [1 ]
CHRISTENSEN, LH [1 ]
NIELSEN, J [1 ]
机构
[1] TECH UNIV DENMARK,DEPT BIOTECHNOL,DK-2800 LYNGBY,DENMARK
关键词
ENZYMATIC METHODS; FLOW INJECTION; UV VISIBLE SPECTROPHOTOMETRY; ANTIBIOTICS; ENZYME REACTORS; FERMENTATION; IODIMETRY; PENICILLIN;
D O I
10.1016/0003-2670(93)80611-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three different flow-injection analysis systems for measuring penicillins in complex fermentation media were tested: a molybdenum blue, an iodimetric and a potentiometric method. All the methods are based on enzymatic hydrolysis of the penicillin to the corresponding penicilloic acid using beta-lactamase, followed by detection of penicilloic acid. The beta-lactamase is immobilized in a packed-bed reactor in which there is 100% conversion of penicillin to penicilloic acid, and all the methods therefore measure the sum of penicilloic acid and penicillin in the sample. The iodimetric method was found to be the best method for measurement in fermentation media. By replacing the enzyme reactor with an enzyme-free dummy reactor, it is possible to measure the concentration of penicilloic acid alone, and thence the penicillin concentration can be determined by subtraction of the penicilloic acid concentration from the total response in the analyser with the enzyme reactor inserted. The application of the analyser was tested by monitoring a fed-batch penicillin fermentation and the correlation between measurements by the FIA system and a liquid chromatographic method was very good.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 22 条
[1]   CHARACTERIZATION AND APPLICATION OF PRECISE AND ROBUST FLOW-INJECTION ANALYZERS FOR ONLINE MEASUREMENT DURING FERMENTATIONS [J].
BENTHIN, S ;
NIELSEN, J ;
VILLADSEN, J .
ANALYTICA CHIMICA ACTA, 1991, 247 (01) :45-50
[2]   PENICILLIN-G SENSOR BASED ON PENICILLIN AMIDASE COUPLED TO A FIELD-EFFECT TRANSISTOR [J].
BRAND, U ;
SCHEPER, T ;
SCHUGERL, K .
ANALYTICA CHIMICA ACTA, 1989, 226 (01) :87-97
[3]   MONITORING OF SUBSTRATES AND PRODUCTS DURING FED-BATCH PENICILLIN FERMENTATIONS ON COMPLEX MEDIA [J].
CHRISTENSEN, LH ;
NIELSEN, J ;
VILLADSEN, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :123-136
[4]  
CHRISTENSEN LH, 1992, THESIS TU DENMARK LY
[5]  
CLARKE HT, 1949, CHEM PENICILLIN
[6]   FLOW-INJECTION ANALYSIS WITH ENZYME THERMISTOR DETECTOR FOR AUTOMATED-DETERMINATION OF BETA-LACTAMS [J].
DECRISTOFORO, G ;
DANIELSSON, B .
ANALYTICAL CHEMISTRY, 1984, 56 (02) :263-268
[7]   DESIGN AND RESPONSE CHARACTERISTICS OF AN ENZYME ELECTRODE FOR MEASUREMENT OF PENICILLIN IN FERMENTATION BROTH [J].
ENFORS, SO ;
NILSSON, H .
ENZYME AND MICROBIAL TECHNOLOGY, 1979, 1 (04) :260-264
[8]   SINGLE FIBER-OPTIC FLUORESCENCE ENZYME-BASED SENSOR [J].
FUH, MRS ;
BURGESS, LW ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :433-435
[9]   A FLOW-INJECTION ANALYSIS SYSTEM FOR FERMENTATION MONITORING AND CONTROL [J].
GARN, M ;
GISIN, M ;
THOMMEN, C ;
CEVEY, P .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) :423-428
[10]   FLOW-INJECTION DETERMINATION OF PENICILLINS USING IMMOBILIZED PENICILLINASE IN A SINGLE BEAD STRING REACTOR [J].
GNANASEKARAN, R ;
MOTTOLA, HA .