SUPERIOR MESENTERIC BLOOD-FLOW DURING DIGESTION IN MAN

被引:0
|
作者
NORRYD, C
DENCKER, H
LUNDERQUIST, A
OLIN, T
TYLEN, U
机构
[1] UNIV HOSP LUND,DEPT DIAG RADIOL,LUND,SWEDEN
[2] UNIV HOSP LUND,DEPT SURG,LUND,SWEDEN
来源
ACTA CHIRURGICA SCANDINAVICA | 1975年 / 141卷 / 03期
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
引用
收藏
页码:197 / 202
页数:6
相关论文
共 50 条
  • [21] MESENTERIC BLOOD-FLOW DURING SUBLETHAL ENDOTOXEMIA
    BRUNGARD.JM
    SWAN, KG
    REYNOLDS, DG
    FEDERATION PROCEEDINGS, 1972, 31 (02) : A358 - &
  • [22] SUPERIOR MESENTERIC-ARTERY BLOOD-FLOW IN MAN MEASURED WITH INTRAARTERIAL DOPPLER CATHETERS - EFFECT OF OCTREOTIDE
    MCCORMICK, PA
    SEIFALIAN, AM
    STANSBY, G
    MCGANN, G
    COLLINS, P
    CHIN, J
    MCINTYRE, N
    DICK, R
    BURROUGHS, AK
    JOURNAL OF HEPATOLOGY, 1993, 17 (01) : 20 - 27
  • [23] EFFECTS OF ORAL ALCOHOL ON SUPERIOR MESENTERIC-ARTERY BLOOD-FLOW IN NORMAL MAN, HORIZONTAL AND TILTED
    MAULE, S
    CHAUDHURI, KR
    THOMAIDES, T
    PAVITT, D
    MCCLEERY, J
    MATHIAS, CJ
    CLINICAL SCIENCE, 1993, 84 (04) : 419 - 425
  • [24] POSTPRANDIAL REGULATION OF SUPERIOR MESENTERIC-ARTERY BLOOD-FLOW (SMABF) IN MAN - ROLE OF GASTROINTESTINAL HORMONES
    SIEBER, C
    HILDEBRAND, P
    STALDER, G
    BEGLINGER, C
    GASTROENTEROLOGY, 1988, 94 (05) : A426 - A426
  • [25] TRANS-CUTANEOUS DOPPLER ULTRASOUND MEASUREMENT OF SUPERIOR MESENTERIC-ARTERY BLOOD-FLOW IN MAN
    QAMAR, MI
    READ, AE
    SKIDMORE, R
    EVANS, JM
    WELLS, PNT
    GUT, 1986, 27 (01) : 100 - 105
  • [26] Effect of fat digestion on superior mesenteric artery blood flow in humans
    Symersky, T.
    Huisman, E. J.
    Wasser, M. N. J. M.
    Masclee, A. A. M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2007, 27 (01) : 7 - 11
  • [27] CHANGES IN SUPERIOR MESENTERIC-ARTERY BLOOD-FLOW DURING SYMPATHETIC ACTIVATION IN NORMAL SUBJECTS
    CHAUDHURI, KR
    THOMAIDES, T
    HERNANDEZ, P
    MATHIAS, CJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1991, 438 : P55 - P55
  • [28] COLLATERAL BLOOD-FLOW TO THE INTESTINES AND PANCREAS DURING TOTAL OCCLUSION OF THE SUPERIOR MESENTERIC-ARTERY
    PREMEN, AJ
    WOMACK, WA
    KVIETYS, PR
    GRANGER, DN
    GASTROENTEROLOGY, 1986, 90 (05) : 1590 - 1590
  • [29] DUPLEX SONOGRAPHY BLOOD-FLOW MEASUREMENT IN THE SUPERIOR MESENTERIC-ARTERY
    SCHABERLE, W
    SEITZ, K
    ULTRASCHALL IN DER MEDIZIN, 1991, 12 (06): : 277 - 282
  • [30] BLOOD-FLOW IN THE SUPERIOR MESENTERIC-ARTERY - ESTIMATION WITH DOPPLER US
    TAYLOR, GA
    RADIOLOGY, 1990, 174 (01) : 15 - 16