PROSPECTIVE EXPERIMENTAL-STUDY OF FACTORS RELATED TO POSTERIOR CHAMBER INTRAOCULAR-LENS DECENTRATION

被引:28
作者
LEGLER, UFC [1 ]
ASSIA, EI [1 ]
CASTANEDA, VE [1 ]
HOGGATT, JP [1 ]
APPLE, DJ [1 ]
机构
[1] MED UNIV S CAROLINA,DEPT OPHTHALMOL,171 ASHLEY AVE,CHARLESTON,SC 29425
关键词
CAPSULAR TEAR; CAPSULORHEXIS; DECENTRATION; INTRAOCULAR LENS DIMENSIONS; LOOP FIXATION; POSTERIOR CHAMBER INTRAOCULAR LENS;
D O I
10.1016/S0886-3350(13)80097-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The effect of posterior chamber intraocular lens (IOL) dimensions, design, style, loop fixation, and anterior capsular tears on decentration were investigated in an experimental model. Nine posterior chamber IOLs of various designs and styles with loop diameters between 12.0 and 14.0 mm and optic diameters between 5.0 and 7.0 mm were implanted in human eyes obtained post mortem. Symmetrical and asymmetrical fixation were investigated in eyes with and without radial tears using the Miyake posterior view technique. Location of IOL loops proved to be the most significant factor in IOL decentration. Decentration was least with symmetrical bag/bag fixation and no radial tears (mean = 0.20 +/- 0.05 mm). Asymmetrical bag/sulcus fixation in the presence of anterior capsular tears was associated with the highest decentration rate (mean 0.68 +/- 0.28 mm). Optic size and total loop diameter had no apparent effect on IOL centration in the immediate postoperative period.
引用
收藏
页码:449 / 455
页数:7
相关论文
共 17 条
[1]  
Solomon KD, Apple DJ, Mamalis N, Et al., Complications of intraocular lenses with special reference to an analysis of 2500 explanted intraocular lenses (IOLs), Eur J Implant Refract Surg, 3, pp. 195-200, (1991)
[2]  
Hansen SO, Tetz MR, Solomon KD, Et al., Decentration of flexible loop posterior chamber intraocular lenses in a series of 222 postmortem eyes, Ophthalmology, 95, pp. 344-349, (1988)
[3]  
Apple DJ, Kincaid MC, Mamalis N, Olson RJ, Intraocular Lenses
[4]  
Evolution, Designs, Complications, and Pathology, (1989)
[5]  
Sulewski ME, Stark WJ, Decentration of an all-PMMA posterior chamber intraocular lens due to haptic deformation (letter), Arch Ophthalmol, 109, pp. 316-317, (1991)
[6]  
Davison JA, Analysis of capsular bag defects and intraocular lens positions for consistent centration, J Cataract Refract Surg, 12, pp. 124-129, (1986)
[7]  
Apple DJ, Park SB, Merkley KH, Et al., Posterior chamber intraocular lenses in a series of 75 autopsy eyes. Part I: Loop location, J Cataract Refract Surg, 12, pp. 358-362, (1986)
[8]  
Legler UFC, Apple DJ, Hund P, Kirkconnell WS, Chronic ciliary pain secondary to posterior chamber intraocular lens loop incarceration, Am J Ophthalmol, 111, pp. 513-515, (1991)
[9]  
Miyake K, Miyake C, Intraoperative posterior chamber lens haptic fixation in the human cadaver eye, Ophthalmic Surg, 16, pp. 230-236, (1985)
[10]  
Apple DJ, Lim ES, Morgan RC, Et al., Preparation and study of human eyes obtained postmortem with the Miyake posterior photographic technique, Ophthalmology, 97, pp. 810-816, (1990)