INITIAL EXPERIENCE WITH A NEW SINGLE CHAMBER, DUAL SENSOR RATE-RESPONSIVE PACEMAKER

被引:21
|
作者
CONNELLY, DT
机构
[1] Cardiothoracic Centre, Liverpool
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1993年 / 16卷 / 09期
关键词
SENSOR BLENDING; SENSOR CROSSING; DUAL SENSOR RATE RESPONSIVE PACEMAKER;
D O I
10.1111/j.1540-8159.1993.tb01818.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In August 1991, a new single chamber pacemaker became available that utilizes information from two sensors, activity and stimulus-to-T wave (QT) interval. We are reporting on the first 90 implants in 21 centers. T wave sensing was adequate at implantation in 88/90 patients, with a safety margin of > 100% in 86/90. Activity sensing was adequate in all patients. The contribution of each sensor (sensor blending) is programmable for each patient. Of 75 patients assessed at 1 month after implant, three have been programmed to ''Activity-Only'' mode, and 72 to dual sensor mode. Of these, 18 have been programmed to ''QT < Activity,'' 48 to ''QT = Activity,'' and 6 to ''QT > Activity.'' Forty-five patients underwent exercise testing in dual sensor mode and a subgroup of 15 also underwent exercise testing in Activity-Only mode. The dual sensor mode produced a more gradual increase in pacing rate. Sensor Cross Checking(TM) satisfactorily prevented a sustained high pacing rate in tests of false-positive activity sensing (tapping, vibrating pacemaker, or static pressure). The maximum pacing rate on walking downstairs (94.2 +/- 7.2 ppm) was similar to that produced by walking upstairs (91.6 +/- 5.9 ppm). We conclude that initial assessment of this dual sensor, single chamber, rate responsive pacemaker confirms that the algorithm for combining data from two sensors functions satisfactorily. Dual sensor rate responsive pacing may offer significant advantages over single sensor devices, and further studies of this novel device are indicated.
引用
收藏
页码:1833 / 1841
页数:9
相关论文
共 50 条
  • [41] PHYSIOLOGICAL BENEFITS OF A PACEMAKER WITH DUAL CHAMBER PACING AT LOW HEART-RATES AND SINGLE CHAMBER RATE RESPONSIVE PACING DURING EXERCISE
    FRENCH, WJ
    HASKELL, RJ
    WESLEY, GW
    FLORIO, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1840 - 1845
  • [42] HEMODYNAMIC AND OXYMETRIC INVESTIGATIONS ON PATIENTS UNDER RATE-RESPONSIVE DUAL-CHAMBER STIMULATION DURING EXERCISE
    WEINHOLD, C
    FULLE, P
    MARKEWITZ, A
    STEINBECK, G
    THORACIC AND CARDIOVASCULAR SURGEON, 1992, 40 (05): : 273 - 278
  • [43] An automatic rate profile optimization algorithm: clinical experience with a new rate adaptive dual sensor pacemaker
    Greco, EM
    Arlotti, M
    Ricci, R
    Puglisi, A
    Marotta, T
    DeSeta, F
    Guardini, S
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 471 - 475
  • [44] Rate Responsive Pacing is Associated With Lower Mortality in Dual-chamber Pacemaker Patients
    Sharma, Vinod
    Borlaug, Barry A.
    Abeyratne, Athula
    Cho, Yong
    Chung, Eugene S.
    CIRCULATION, 2017, 136
  • [45] Initial experience with a new dual chamber defibrillator in humans
    Jung, W
    Spehl, S
    Wolpert, C
    Esmailzadeh, B
    Schneider, C
    Tenser, D
    Lewalter, T
    Schumacher, B
    Kirchhoff, PG
    Luderitz, B
    CIRCULATION, 1997, 96 (08) : 1152 - 1152
  • [46] CLINICAL BENEFITS OF ACTIVITY SENSING RATE-RESPONSIVE SINGLE CHAMBER CARDIAC PACING - CLINICAL-RESULTS
    WINTER, UJ
    KOCHS, MG
    HOPP, HW
    EGGELING, T
    HOHER, M
    HOMBACH, V
    HILGER, HH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05): : 1233 - 1233
  • [47] RATE-RESPONSIVE CARDIAC PACING USING A MINUTE VENTILATION SENSOR
    ABRAHAMSEN, AM
    BARVIK, S
    AARSLAND, T
    DICKSTEIN, K
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (08): : 1650 - 1655
  • [48] EXERCISE PERFORMANCE WITH SINGLE CHAMBER RATE-RESPONSIVE PACING IN CONGENITAL HEART-DEFECTS AFTER OPERATION
    PARIDON, SM
    KARPAWICH, PP
    PINSKY, WW
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11): : 1231 - 1233
  • [49] LIMITATIONS OF RATE RESPONSE OF AN ACTIVITY-SENSING RATE-RESPONSIVE PACEMAKER TO DIFFERENT FORMS OF ACTIVITY
    LAU, CP
    MEHTA, D
    TOFF, WD
    STOTT, RJ
    WARD, DE
    CAMM, AJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (02): : 141 - 150
  • [50] Wide QRS complex tachycardia in a patient with a minute ventilation rate-responsive pacemaker
    Mukerji, S
    Khunnawat, C
    Sankaran, S
    Thakur, RK