INITIAL EXPERIENCE WITH A NEW SINGLE CHAMBER, DUAL SENSOR RATE-RESPONSIVE PACEMAKER

被引:21
|
作者
CONNELLY, DT
机构
[1] Cardiothoracic Centre, Liverpool
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1993年 / 16卷 / 09期
关键词
SENSOR BLENDING; SENSOR CROSSING; DUAL SENSOR RATE RESPONSIVE PACEMAKER;
D O I
10.1111/j.1540-8159.1993.tb01818.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In August 1991, a new single chamber pacemaker became available that utilizes information from two sensors, activity and stimulus-to-T wave (QT) interval. We are reporting on the first 90 implants in 21 centers. T wave sensing was adequate at implantation in 88/90 patients, with a safety margin of > 100% in 86/90. Activity sensing was adequate in all patients. The contribution of each sensor (sensor blending) is programmable for each patient. Of 75 patients assessed at 1 month after implant, three have been programmed to ''Activity-Only'' mode, and 72 to dual sensor mode. Of these, 18 have been programmed to ''QT < Activity,'' 48 to ''QT = Activity,'' and 6 to ''QT > Activity.'' Forty-five patients underwent exercise testing in dual sensor mode and a subgroup of 15 also underwent exercise testing in Activity-Only mode. The dual sensor mode produced a more gradual increase in pacing rate. Sensor Cross Checking(TM) satisfactorily prevented a sustained high pacing rate in tests of false-positive activity sensing (tapping, vibrating pacemaker, or static pressure). The maximum pacing rate on walking downstairs (94.2 +/- 7.2 ppm) was similar to that produced by walking upstairs (91.6 +/- 5.9 ppm). We conclude that initial assessment of this dual sensor, single chamber, rate responsive pacemaker confirms that the algorithm for combining data from two sensors functions satisfactorily. Dual sensor rate responsive pacing may offer significant advantages over single sensor devices, and further studies of this novel device are indicated.
引用
收藏
页码:1833 / 1841
页数:9
相关论文
共 50 条
  • [1] PRELIMINARY EXPERIENCE WITH AN ACTIVITY REGULATED RATE-RESPONSIVE SINGLE-CHAMBER PACEMAKER
    CASHION, WR
    SPENCER, WH
    NIELSEN, AP
    SCHUENEMEYER, TD
    GRIFFIN, JC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03): : 466 - 466
  • [2] Initial experience with dual-sensor rate-responsive pacemakers in children
    Celiker, A
    Alehan, D
    Tokel, NK
    Lenk, MK
    Ozme, S
    EUROPEAN HEART JOURNAL, 1996, 17 (08) : 1251 - 1255
  • [3] CLINICAL-EVALUATION OF A DUAL SENSOR, RATE-RESPONSIVE PACEMAKER
    SINHA, S
    SCHILLING, RJ
    KAYE, GC
    CAPLIN, JL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1950 - 1954
  • [4] Single-chamber, rate-responsive pacemaker-mediated tachycardia
    Bohm, Adam
    Kiss, Robert
    Dorian, Paul
    Pinter, Arnold
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 (09) : E340 - E340
  • [5] CLINICAL-EXPERIENCE WITH A NEW RATE-RESPONSIVE TX PACEMAKER
    YASUNO, M
    NISHINO, Y
    NISHINO, M
    AKASHI, T
    TANAHASHI, H
    KOBAYASHI, K
    YAMADA, Y
    INOUE, M
    ANGIOLOGY, 1986, 37 (12) : 888 - 895
  • [6] DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF AN IMPEDANCE-BASED DUAL-CHAMBER RATE-RESPONSIVE PACEMAKER
    BURNS, CA
    SPERRY, RE
    ARROWOOD, JA
    WOOD, MA
    NIXON, JV
    ELLENBOGEN, KA
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (07): : 569 - 574
  • [7] ARTIFACT WITH RATE-RESPONSIVE PACEMAKER
    JENKINS, IR
    TOWLER, SCB
    ANAESTHESIA AND INTENSIVE CARE, 1993, 21 (03) : 375 - 376
  • [8] DUAL CHAMBER RATE-RESPONSIVE PACING - FEASIBILITY STUDIES IN DDD PATIENTS USING CONTINUOUS PACEMAKER REPROGRAMMING
    REYNOLDS, D
    GOLI, V
    BENNETT, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 419 - 419
  • [9] DUAL CHAMBER RATE-RESPONSIVE PACING - FEASIBILITY STUDIES IN DDD PATIENTS USING CONTINUOUS PACEMAKER REPROGRAMMING
    REYNOLDS, D
    GOLI, V
    BENNETT, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 733 - 733
  • [10] RATE-RESPONSIVE PACING IN IMMATURE CANINES - EXERCISE RESPONSE WITH SINGLE AND DUAL CHAMBER MODES
    KARPAWICH, PP
    JUSTICE, C
    CAVITT, DL
    CIRCULATION, 1987, 76 (04) : 550 - 550