Out of touch - A plugin for controlling OsiriX with gestures using the leap controller

被引:23
作者
Ebert, L. C. [1 ]
Flach, P. M. [1 ,2 ]
Thali, M. J. [1 ]
Ross, S. [1 ]
机构
[1] Univ Zurich, Inst Forens Med, Winterthurerstr 190-52, CH-8057 Zurich, Switzerland
[2] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Zurich, Switzerland
关键词
Virtopsy; Forensic imaging; Gesture control; Medical image viewer; OsiriX; CT; Leap;
D O I
10.1016/j.jofri.2014.05.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: in recent years, different, systems for gesture control of medical devices have been presented. Today, low-cost gesture control systems are commercially available. In this article, we present a plugin for the OsiriX medical image viewer, which operates the viewer using finger gestures. Materials and methods: We use a device called the Leap controller for gesture control input. The device has a low cost, and it uses structured light to create a depth image of the screen. The drivers provided by the manufacturer allow for easy integration into existing software projects. The presented plugin features gestures for panning, zooming, windowing and browsing of medical image datasets. Conclusion: Gesture control technology is becoming increasingly robust and available. We therefore expect that gesture control solutions will be increasingly implemented in medical environments. For broad acceptance of such technologies, standard gestures for certain actions should be standardized in the future. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:126 / 128
页数:3
相关论文
共 8 条
[1]   Invisible touch-Control of a DICOM viewer with finger gestures using the Kinect depth camera [J].
Ebert, L. C. ;
Hatch, G. ;
Thali, M. J. ;
Ross, S. .
JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2013, 1 (01) :10-14
[2]   Getting in touch-3D printing in Forensic Imaging [J].
Ebert, Lars Chr. ;
Thali, Michael J. ;
Ross, Steffen .
FORENSIC SCIENCE INTERNATIONAL, 2011, 211 (1-3) :E1-E6
[3]   Computer keyboard and mouse as a reservoir of pathogens in an intensive care unit [J].
Hartmann B. ;
Benson M. ;
Junger A. ;
Quinzio L. ;
Röhrig R. ;
Fengler B. ;
Färber U.W. ;
Wille B. ;
Hempelmann G. .
Journal of Clinical Monitoring and Computing, 2004, 18 (1) :7-12
[4]   PACS for surgery and interventional radiology: Features of a Therapy Imaging and Model Management System (TIMMS) [J].
Lemke, Heinz U. ;
Berliner, Leonard .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (02) :239-242
[5]   OsiriX: An open-source software for navigating in multidimensional DICOM images [J].
Rosset, A ;
Spadola, L ;
Ratib, O .
JOURNAL OF DIGITAL IMAGING, 2004, 17 (03) :205-216
[6]  
Thali MJ, 2003, J FORENSIC SCI, V48, P386
[7]   A gesture-based tool for sterile browsing of radiology images [J].
Wachs, Juan P. ;
Stern, Helman I. ;
Edan, Yael ;
Gillam, Michael ;
Handler, Jon ;
Feied, Craig ;
Smith, Mark .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2008, 15 (03) :321-323
[8]   Analysis of the Accuracy and Robustness of the Leap Motion Controller [J].
Weichert, Frank ;
Bachmann, Daniel ;
Rudak, Bartholomaeus ;
Fisseler, Denis .
SENSORS, 2013, 13 (05) :6380-6393