ACCURACY OF THE NEWER GENERATION INTRAOCULAR-LENS POWER CALCULATION FORMULAS IN LONG AND SHORT EYES

被引:71
作者
OLSEN, T
THIM, K
CORYDON, L
机构
[1] Department of Ophthalmology, Vejle Sygehus, Vejle
关键词
BIOMETRY; CATARACT SURGERY; FORMULA ACCURACY; INTRAOCULAR LENS POWER CALCULATION; PSEUDOPHAKIC ANTERIOR CHAMBER DEPTH; REGRESSION; THEORETICAL FORMULA;
D O I
10.1016/S0886-3350(13)80249-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The accuracy of two newer generation theoretical intraocular lens (IOL) power calculation formulas and of the empirical SRK I and II formulas was evaluated in a series of 500 IOL implantations including a series of unusually long and short eyes. The prediction error of the theoretical formulas was found to be largely unaffected by the variation in axial length and corneal power, while the prediction of the SRK I formula was less accurate in the short and long eyes. The prediction of the SRK II formula was more accurate than the SRK I in that no systematic offset error with axial length could be demonstrated. However, because of a relatively larger scatter in the long eyes and a significant bias with the corneal power, the absolute error of the SRK II formula was higher than that of the theoretical formulas in the long eyes. The higher accuracy of the newer generation theoretical formulas was attributed to their improved prediction of the pseudophakic anterior chamber depth.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 28 条
[1]  
Lepper RD, Trier HG, Refraction after intraocular lens implantation: results with a computerized system for ultrasonic biometry and for implant lens power calculation, Doc Ophthalmol Proc Ser, 38, pp. 243-248, (1984)
[2]  
Holladay JT, Musgrove KH, Prager TC, Et al., A three-part system for refining intraocular lens power calculations, J Cataract Refract Surg, 14, pp. 17-24, (1988)
[3]  
Sanders DR, Retzlaff J, Kraff MC, Comparison of the SRK IIT" formula and other second generation formulas, J Cataract Refract Surg, 14, pp. 136-141, (1988)
[4]  
Olsen T, Thim K, Corydon L, Theoretical versus SRK I and SRK II calculation of intraocular lens power, J Cataract Refract Surg, 16, pp. 217-225, (1990)
[5]  
Thompson JT, Maumenee AE, Baker CC, A new posterior chamber intraocular lens formula for axial myopes, Ophthalmology, 91, pp. 485-488, (1984)
[6]  
Donzis PB, Kastl PR, Gordon RA, An intraocular lens formula for short, normal and long eyes, CLAD J, 11, pp. 95-98, (1985)
[7]  
Drews RC, Reliability of lens implant power formulas in hyperopes and myopes, Ophthalmic Surg, 19, pp. 11-15, (1988)
[8]  
Huber C, Effectiveness of intraocular lens calculation in high ametropia, J Cataract Refract Surg, 15, pp. 667-672, (1989)
[9]  
Schelenz J, Kamman J, Die Biometrie des Pseudophakos an hoch myopen Augen, Kongress der DGII 1988. Ferdinand Enke Verlag, pp. 11-16, (1989)
[10]  
Olsen T, Theoretical approach to intraocular lens calculation using Gaussian optics, J Cataract Refract Surg, 13, pp. 141-145, (1987)