EFFECT OF SKIN CONCAVITY ON SUBCUTANEOUS TISSUE-FLUID PRESSURE

被引:5
作者
ADAIR, TH
VANCE, GA
MONTANI, JP
GUYTON, AC
机构
来源
AMERICAN JOURNAL OF PHYSIOLOGY | 1991年 / 261卷 / 02期
关键词
LYMPHATIC SYSTEM; INTERSTITIUM; MICROCIRCULATION; INTERSTITIAL FLUID PRESSURE;
D O I
10.1152/ajpheart.1991.261.2.H349
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We tested the hypothesis that mechanical factors associated with a skin concavity can cause the local tissue fluid pressure to become more negative. Perforated Teflon collars, 26 mm in diameter and having various heights (5, 10, 13, and 16 mm), were implanted into the fascial plane of the inguinal and abdominal areas of six sheep. After several weeks, visible signs of edema were no longer apparent, and the skin formed a concavity within the center of each collar. The depth of each concavity was measured using an electronic micrometer, and the tissue fluid pressure beneath the concavity was measured using a needle method. Over the entire range of collar heights, the average depth of the concavities ranged from 1.1 to 4.7 mm in the abdominal tissues and from 1.8 to 5.5 mm in the inguinal tissues. The respective values of tissue fluid pressure averaged -4.6 to -13.0 and -5.7 to -12.8 mmHg. The results therefore indicate that implanting deeper collars leads to the formation of deeper concavities in the skin and also to greater negativity in the free tissue fluid pressure beneath the skin. Linear regression extrapolation to a collar height of 0 mm corresponded to a tissue fluid pressure of -1.0 mmHg in the abdominal tissue and -2.4 mmHg in the inguinal tissues. A model based on excessive pumping of the lymphatic system in the vicinity of a concavity is provided to explain this newly described phenomenon. We conclude that mechanical factors associated with the formation of a skin concavity cause or permit the tissue fluid pressure to reach levels of negativity far greater than those that exist in the absence of a concavity.
引用
收藏
页码:H349 / H353
页数:5
相关论文
共 16 条
[1]   MEASUREMENT OF SUBCUTANEOUS TISSUE-FLUID PRESSURE USING A SKIN-CUP METHOD [J].
ADAIR, TH ;
GUYTON, AC .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (05) :1528-1535
[2]  
ADAIR TH, 1983, TECHNIQUES LIFE SCI, V3, P1
[3]  
Adair TH, 1985, EXPT BIOL LYMPHATIC, P13
[4]   INTERSTITIAL FLUID VOLUME - LOCAL REGULATORY MECHANISMS [J].
AUKLAND, K ;
NICOLAYSEN, G .
PHYSIOLOGICAL REVIEWS, 1981, 61 (03) :556-643
[5]   RE-EVALUATION OF NEEDLE METHOD FOR MEASURING INTERSTITIAL FLUID PRESSURE [J].
BRACE, RA ;
GUYTON, AC ;
TAYLOR, AE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1975, 229 (03) :603-607
[6]   ULTRASTRUCTURE OF CONJUNCTIVAL LYMPHATIC ANCHORING FILAMENTS [J].
COLLIN, HB .
EXPERIMENTAL EYE RESEARCH, 1969, 8 (02) :102-&
[7]  
FUNG YC, 1981, BIOMECHANICS, P16
[8]   ROLE OF THE INTERSTITIAL MATRIX AND LYMPHATIC PUMP IN REGULATION OF TRANS-CAPILLARY FLUID BALANCE [J].
GRANGER, HJ .
MICROVASCULAR RESEARCH, 1979, 18 (02) :209-216
[9]   INTERSTITIAL FLUID PRESSURE [J].
GUYTON, AC ;
GRANGER, HJ ;
TAYLOR, AE .
PHYSIOLOGICAL REVIEWS, 1971, 51 (03) :527-&