NEW NEUTRAL CARRIER-BASED H+ SELECTIVE-MEMBRANE ELECTRODES

被引:77
作者
COSOFRET, VV [1 ]
NAHIR, TM [1 ]
LINDNER, E [1 ]
BUCK, RP [1 ]
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1992年 / 327卷 / 1-2期
关键词
D O I
10.1016/0022-0728(92)80142-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
H+-selective membrane electrodes based on two neutral ion carriers of the class of phenoxazine derivatives which contain different lipophilic imino chains (9-(diethylamino)-5-octadecanoylimino-5H-benzo[a]phenoxazine and 9-(dimethylamino)-5-[4-(16-butyl-2,14-dioxo-3,15-dioxaeicosyl)phenylimino]-5H-benzo[a]phenoxazine respectively) are described. Both ionophores, previously used as chromo-ionophores in optode construction, with added potassium tetrakis(p-chlorophenyl) borate (KTpClPB) as cation exchanger sites were embedded into a high molecular weight poly(vinyl chloride) matrix containing o-nitrophenyl octyl ether (o-NPOE) as plasticizer. Both polymeric pH electrodes exhibited near -Nernstian responses over the ranges depending on the pK of the ionophore within the membrane used as electroactive material. The selectivities and other main characteristics of the electrodes are presented.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 32 条
[1]   NEUTRAL CARRIER BASED HYDROGEN-ION SELECTIVE MICROELECTRODE FOR EXTRACELLULAR AND INTRACELLULAR STUDIES [J].
AMMANN, D ;
LANTER, F ;
STEINER, RA ;
SCHULTHESS, P ;
SHIJO, Y ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1981, 53 (14) :2267-2269
[2]  
BAILEY PL, 1980, ANAL ION SELECTIVE E, P49
[3]  
BUCK RP, 1991, 1991 P POL MAT SCI E, P360
[4]  
CHAO R, 1988, PFLUGERS ARCH, V411, P216
[5]   APPLICATION OF AZOLES AS NEUTRAL CARRIERS IN LIQUID MEMBRANE ION-SELECTIVE PH ELECTRODES [J].
CHOJNACKI, J ;
BIERNAT, JF .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 277 (1-2) :159-164
[6]   EVALUATION OF A DUAL-FUNCTION PH AND PCO-2 INVIVO SENSOR [J].
COON, RL ;
LAI, NCJ ;
KAMPINE, JP .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (04) :625-629
[7]   A QUINIDINE-RESPONSIVE PLASTIC MEMBRANE-ELECTRODE [J].
COSOFRET, VV ;
BUCK, RP .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1985, 3 (02) :123-130
[8]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544
[9]   LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS [J].
DINTEN, O ;
SPICHIGER, UE ;
CHANIOTAKIS, N ;
GEHRIG, P ;
RUSTERHOLZ, B ;
MORF, WE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :596-603
[10]   H+-SELECTIVE ELECTRODES BASED ON NEUTRAL CARRIERS - SPECIFIC FEATURES IN BEHAVIOR AND QUANTITATIVE DESCRIPTION OF THE ELECTRODE RESPONSE [J].
EGOROV, VV ;
LUSHCHIK, YF .
TALANTA, 1990, 37 (05) :461-469