FILM DOSIMETRY OF CLINICAL ELECTRON-BEAMS

被引:29
|
作者
VANBATTUM, LJ
HUIZENGA, H
机构
[1] Dr Daniel den Hoed Cancer Centre, 3075 EA Rotterdam
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 18卷 / 01期
关键词
Electron beams; Film dosimetry;
D O I
10.1016/0360-3016(90)90269-P
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Film dosimetry is used widely to obtain relative dose distributions of clinical electron beams in phantoms. Nevertheless, measurement results obtained with film dosimetry may lack precision and reliability. In this paper well defined and reproducible methods in film dosimetry are discussed. By application of these methods, film dosimetry appears to be adequate in measuring relative dose distributions of clinically applied electron beams, with an accuracy of 1% to 2% of the dose maximum, in water and plastics as well as in heterogeneously composed material. © 1990.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [31] Film dosimetry for intensity modulated radiation therapy
    Benites-Rengifo, J
    Martínez-Dávalos, A
    Celis, M
    Lárraga, J
    MEDICAL PHYSICS, 2004, 724 : 244 - 248
  • [32] Direct measurement of ionization chamber absorbed dose kQ factors in clinical electron beams
    Wang, Zhipeng
    Xing, Shuming
    Wang, Kun
    Jin, Sunjun
    Zhang, Jian
    Fan, Fuyou
    RADIATION MEASUREMENTS, 2020, 139
  • [33] The importance of electron-electron bremsstrahlung for terrestrial gamma-ray flashes, electron beams and electron-positron beams
    Kohn, C.
    Ebert, U.
    Mangiarotti, A.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2014, 47 (25)
  • [34] Spectral analysis of the EBT3 radiochromic films for clinical photon and electron beams
    Leon-Marroquin, Elsa Y.
    Mulrow, Daniel J.
    Khan, Rao
    Darafsheh, Arash
    MEDICAL PHYSICS, 2019, 46 (02) : 973 - 982
  • [35] Particle waves in electron beams
    Sadovoi, G. S.
    2005 Microwave Electronics: Measurements, Identification, Applications, 2005, : 20 - 21
  • [36] VIRTUAL SOURCE DISTANCES AND FIELD GEOMETRY INDEPENDENT OUTPUT FACTORS FOR 5-14 MEV ELECTRON-BEAMS FROM A SIEMENS MEVATRON-M7145
    PLANE, JH
    TREVOR, MM
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (776) : 717 - 719
  • [37] On multichannel film dosimetry with channel-independent perturbations
    Mendez, I.
    Peterlin, P.
    Hudej, R.
    Strojnik, A.
    Casar, B.
    MEDICAL PHYSICS, 2014, 41 (01)
  • [38] Positively charged electron beams
    Martens, V. Ya
    VACUUM, 2022, 203
  • [39] Radiochromic film containing methyl viologen for radiation dosimetry
    Lavalle, M.
    Corda, U.
    Fuochi, P. G.
    Caminati, S.
    Venturi, M.
    Kovacs, A.
    Baranyai, M.
    Safrany, A.
    Miller, A.
    RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (8-9) : 1502 - 1506
  • [40] DOSIMETRY AND CLINICAL IMPLEMENTATION OF DYNAMIC WEDGE
    KLEIN, EE
    LOW, DA
    MEIGOONI, AS
    PURDY, JA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (03): : 583 - 592