THE MICRO-TRAP - AN ALTERNATIVE TO CRYOFOCUSING IN CAPILLARY GAS-CHROMATOGRAPHY

被引:27
|
作者
FRANK, W [1 ]
FRANK, H [1 ]
机构
[1] UNIV TUBINGEN,INST TOXIKOL,WILHELMSTR 56,W-7400 TUBINGEN 1,GERMANY
关键词
Airborne halocarbons; Capillary columns; Gas chromatography; Micro-trap; Trace analysis;
D O I
10.1007/BF02261224
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For routine analyses involving numerous samples or for field operation of on-site instruments, cryogenic traps are inconvenient: their operation is timeconsuming and automation is technically demanding. complete trapping and efficient band-focussing may be achieved at ambient temperature with micro-traps packed with suitable sorbents. Two approaches have been evaluated: if the boiling points of the analytes are within a range of about 100°C, a single-sorbent trap and direct coupling to the column are recommended; for samples containing components wih widely different volatilities, a trap composed of two or more segments with complementary affinties and coupling to the chromatographic column under carrier-gas flow-reversion is preferable. The procedure has been evaluated for airborne C1 and C2-halocarbons; it is also applicable to trace analysis of other volatile organic air pollutants. © 1990 Friedr. Vieweg & Sohn Verlagsgesellschaft mbH.
引用
收藏
页码:571 / 574
页数:4
相关论文
共 50 条
  • [1] REDUCTION OF PLUG LENGTH IN CAPILLARY GAS CHROMATOGRAPHY USING AN ON-COLUMN MICRO-TRAP
    BARTEL, EE
    VANDERWA.SJ
    JOURNAL OF GAS CHROMATOGRAPHY, 1968, 6 (07): : 396 - &
  • [2] SIMPLE DEVICE FOR ON-COLUMN CRYOFOCUSING IN CAPILLARY COLUMN GAS-CHROMATOGRAPHY
    ROTHCHILD, R
    DEFOREST, PR
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1982, 5 (06): : 321 - 321
  • [3] OPTIMAL CONDITIONS OF PURGE TRAP ON-COLUMN CRYOFOCUSING METHOD WITH CAPILLARY GAS-CHROMATOGRAPHY FOR DETERMINATION OF VOLATILE HALOGENATED HYDROCARBONS IN AQUEOUS SAMPLES
    JUNG, W
    FUJITA, M
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1991, 37 (05): : 395 - 400
  • [4] CRYOFOCUSING IN THE COMBINATION OF GAS-CHROMATOGRAPHY WITH EQUILIBRIUM HEADSPACE SAMPLING
    KOLB, B
    LIEBHARDT, B
    ETTRE, LS
    CHROMATOGRAPHIA, 1986, 21 (06) : 305 - 311
  • [5] CRYOFOCUSING INLET WITH REVERSE FLOW SAMPLE COLLECTION FOR GAS-CHROMATOGRAPHY
    KLEMP, MA
    AKARD, ML
    SACKS, RD
    ANALYTICAL CHEMISTRY, 1993, 65 (18) : 2516 - 2521
  • [6] CRYOGENIC TECHNIQUES IN GAS-CHROMATOGRAPHY .2. CRYOFOCUSING AND CRYOGENIC TRAPPING
    BRETTELL, TA
    GROB, RL
    AMERICAN LABORATORY, 1985, 17 (11) : 50 - &
  • [7] Penning micro-trap for quantum computing
    Jain, Shreyans
    Sagesser, Tobias
    Hrmo, Pavel
    Torkzaban, Celeste
    Stadler, Martin
    Oswald, Robin
    Axline, Chris
    Bautista-Salvador, Amado
    Ospelkaus, Christian
    Kienzler, Daniel
    Home, Jonathan
    NATURE, 2024, 627 (8004) : S29 - S31
  • [8] ANALYSIS OF NATURAL-GAS BY MICRO PACKED CAPILLARY COLUMN GAS-CHROMATOGRAPHY
    ALTHAMIR, WK
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1985, 8 (03): : 143 - 143
  • [9] SELECTIVITY IN CAPILLARY GAS-CHROMATOGRAPHY
    BLOMBERG, L
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (04): : 208 - 208
  • [10] CAPILLARY GAS-CHROMATOGRAPHY OF ALKYLQUINOLINES
    BERLIZOV, YS
    NABIVACH, VM
    DMITRIKOV, VP
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1987, 42 (06): : 891 - 895