Theoretical investigations for combination optical fiber tip sensors

被引:1
作者
Wang, Yong-Jiao [1 ,2 ]
Liang, Lei [1 ]
Yuan, Yin-Quan [1 ]
机构
[1] Wuhan Univ Technol, Natl Engn Lab Fiber Opt Sensing Technol, Wuhan 430070, Hubei, Peoples R China
[2] Henan Univ Urban Construct, Sch Comp Sci & Engn, Pingdingshan, Henan, Peoples R China
基金
美国国家科学基金会;
关键词
Optical fiber biosensor; microstructured fiber; fluorescence;
D O I
10.3233/JCM-150524
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For the optical fiber biosensor made of combination optical fiber tip, the effects of the refractive index (RI) of outer medium and the geometrical parameters of combination optical fiber tip on two important quantities have been investigated. One factor is the total intensity of the evanescent wave into fluorescent layer through core-medium interface; the other is the intensity of the fluorescence signal transmitted from fluorescent layer to measurement end. Theoretical investigations show that the two quantities are dependent upon the RI of outer medium, and the total intensity of the evanescent wave into fluorescent layer increases with the increase of taper angle, and the fluorescence signal arrived at the measurement end gets larger value for shorter fiber tip when the RI of outer medium is smaller than the RI of fiber core.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 12 条
[1]   A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :249-256
[2]   Influence of depressed-index outer ring on evanescent tunneling loss in tapered double-cladding fibers [J].
Chen, Nan-Kuang ;
Hsu, Kuei-Chu ;
Liaw, Shien-Kuei ;
Lai, Yinchieh ;
Chi, Sien .
OPTICS LETTERS, 2008, 33 (15) :1666-1668
[3]   EVANESCENT-ABSORPTION COEFFICIENT FOR DIFFUSE SOURCE ILLUMINATION - UNIFORM-FIBER AND TAPERED-FIBER SENSORS [J].
GUPTA, BD ;
SINGH, CD .
APPLIED OPTICS, 1994, 33 (13) :2737-2742
[4]   A review of fiber-optic biosensors [J].
Leung, Angela ;
Shankar, P. Mohana ;
Mutharasan, Raj .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 125 (02) :688-703
[5]   Effects of geometry on transmission and sensing potential of tapered fiber sensors [J].
Leung, Angela ;
Rijal, Kishan ;
Shankar, P. Mohana ;
Mutharasan, Raj .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (12) :2202-2209
[6]   Improved fluorescence signal with tapered polymer optical fibers under side-illumination [J].
Pulido, C. ;
Esteban, O. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :190-194
[7]   Detection of vathoizen Escherichia coli O157:H7 AT 70 cells/mL using antibody-immobilized biconical tapered fiber sensors [J].
Rijal, K ;
Leung, A ;
Shankar, PM ;
Mutharasan, R .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :871-880
[8]   Absorption-based fiber optic surface plasmon resonance sensor: a theoretical evaluation [J].
Sharma, AK ;
Gupta, BD .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 100 (03) :423-431
[9]   Sensitive liquid refractive index sensors using tapered optical fiber tips [J].
Tai, Yi-Hsin ;
Wei, Pei-Kuen .
OPTICS LETTERS, 2010, 35 (07) :944-946
[10]   Fluorophore-mediated, fiber-optic, multi-analyte, immunosensing system for rapid diagnosis and prognosis of cardiovascular diseases [J].
Tang, Liang ;
Ren, Yongjie ;
Hong, Bin ;
Kang, Kyung A. .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)